At high frequency, alternating current does not use the full cross-section of a conductor. It crowds toward the surface and decays exponentially inward, so the effective conducting cross-section shrinks as frequency rises. The characteristic length of that decay is the skin depth δ\delta. This tool computes δ\delta, the planar surface resistance RsR_s, and the remaining field amplitude at any depth for copper or for a custom conductor, from 1 Hz to 1 THz.

Input

Copper model: 58 MS/m, relative permeability 1. Good-conductor estimate; properties assumed constant. Use Advanced for custom properties.

Load a stated copper or aluminum model. Custom is initially selected; choose Advanced to enter your own properties.
Sinusoidal AC frequency. Enter up to six decimal places. Converted frequency must be 1 Hz–1 THz. Slider starts at 0.01–100 in the selected unit and expands for typed values.
MHz

1,000,000 Hz

Changing the prefix reinterprets the entered number. For example, 1 MHz becomes 1 kHz; the number is not converted.
Visual
Amplitude decay into a good conductor over the first 250 micrometres
Output
Estimated skin depth δ
66.09 µm

Amplitude falls to 1/e ≈ 36.8% at one skin depth.

Understanding the Skin Depth Formula

For a good conductor in sinusoidal steady state, the skin depth is

δ=1πfμσ=2ωμσ=2ωμ0μrσ\delta = \frac{1}{\sqrt{\pi f \mu \sigma}} = \sqrt{\frac{2}{\omega \mu \sigma}} = \sqrt{\frac{2}{\omega \mu_0 \mu_r \sigma}}

where:

Symbol Meaning SI unit
ff Frequency Hz
ω=2πf\omega = 2\pi f Angular frequency rad/s
σ\sigma Electrical conductivity S/m
μ=μ0μr\mu = \mu_0 \mu_r Absolute permeability H/m
μ0\mu_0 Vacuum permeability, 1.25663706127×10−6 H/m1.25663706127 \times 10^{-6}\ \text{H/m} H/m
μr\mu_r Relative permeability (dimensionless real scalar) –
δ\delta Skin depth m (displayed in µm)

The calculator uses the NIST 2022 CODATA value of μ0\mu_0. Since the 2019 SI redefinition, μ0\mu_0 is a measured constant and is no longer exactly 4π×10−7 H/m4\pi \times 10^{-7}\ \text{H/m}. The difference is about 10−1010^{-10} in relative terms and has no practical effect, but the engine uses the current recommended value.

Three scaling facts follow directly from the formula:

  • δ∝1/f\delta \propto 1/\sqrt{f}. A 100× increase in frequency reduces δ\delta by 10×.
  • δ∝1/σ\delta \propto 1/\sqrt{\sigma}. A conductor with one quarter of copper's conductivity has a skin depth twice as large.
  • δ∝1/μr\delta \propto 1/\sqrt{\mu_r}. A magnetic conductor confines current to a thinner layer, at least where μr\mu_r is genuinely high at the frequency of interest.

For copper, a convenient rule is δ≈66.09 mm/f [Hz]\delta \approx 66.09\ \text{mm}/\sqrt{f\,[\text{Hz}]}, or δ≈66.09 μm\delta \approx 66.09\ \mu\text{m} at 1 MHz.

Validity of the good-conductor approximation

The formula assumes conduction current dominates displacement current, i.e. σ≫ωϵ\sigma \gg \omega\epsilon. For copper at 10 GHz, ωϵ0≈0.56 S/m\omega\epsilon_0 \approx 0.56\ \text{S/m} against σ=5.8×107 S/m\sigma = 5.8 \times 10^7\ \text{S/m}, a ratio near 10−810^{-8}, so the approximation is excellent across the entire RF and microwave range. It fails only for poor conductors (lossy dielectrics, doped semiconductors, seawater at high frequency) where ωϵ\omega\epsilon approaches σ\sigma. At cryogenic temperatures and very high frequencies, the electron mean free path can exceed δ\delta (the anomalous skin effect), which this classical model does not capture.

Deriving the Skin Depth Equation from Maxwell's Equations

Inside a homogeneous conductor with negligible displacement current, Maxwell's curl equations combine into a diffusion equation for the phasor current density:

∇2J=jωμσ J\nabla^2 \mathbf{J} = j\omega\mu\sigma\,\mathbf{J}

For a plane conductor occupying x≥0x \ge 0 with current flowing parallel to the surface, this reduces to one dimension:

d2Jdx2=γ2J,γ2=jωμσ\frac{d^2 J}{dx^2} = \gamma^2 J, \qquad \gamma^2 = j\omega\mu\sigma

Taking the root that decays into the conductor gives

γ=jωμσ=1+jδ,J(x)=J(0) e−x/δ e−jx/δ\gamma = \sqrt{j\omega\mu\sigma} = \frac{1+j}{\delta}, \qquad J(x) = J(0)\, e^{-x/\delta}\, e^{-jx/\delta}

The magnitude and phase are therefore:

∣J(x)∣∣J(0)∣=exp⁡(−xδ)\frac{|J(x)|}{|J(0)|} = \exp\left(-\frac{x}{\delta}\right)

Two consequences are worth stating explicitly. First, the real and imaginary parts of γ\gamma are equal, so the phase of the current lags by one radian per skin depth of penetration. Second, the amplitude decays by a factor ee over one δ\delta, not by any sharp cutoff.

How to Use the Skin Depth Calculator

Simple mode (Copper)

Simple mode fixes the material at standard annealed copper: σ=58 MS/m=5.8×107 S/m\sigma = 58\ \text{MS/m} = 5.8 \times 10^7\ \text{S/m} and μr=1\mu_r = 1. Enter a frequency and choose its unit. The result is the skin depth in µm.

Advanced mode (Custom conductor)

Advanced mode exposes every parameter of the model.

Input Range Step Default Notes
Frequency 10−610^{-6} to 101210^{12} 0.01 1 Slider spans 0.01–100 in the selected unit and expands to follow typed values.
Frequency unit Hz, kHz, MHz, GHz – MHz Switching units reinterprets the typed number: entering 1 then selecting kHz means 1 kHz, not 1000 kHz.
Conductivity σ\sigma 0.01–100 MS/m 0.01 58 MS/m 1 MS/m = 10610^6 S/m.
Relative permeability μr\mu_r 0.1–10,000 0.1 1.0 Real scalar, μ/μ0\mu/\mu_0.
Observation depth xx 0–1000 mm 0.001 mm 0.1 mm Distance inward from the surface.

Advanced mode returns three results: the skin depth δ\delta in µm, the planar surface resistance RsR_s in mΩ/□, and the amplitude percentage 100 e−x/δ%100\,e^{-x/\delta}\% at the observation depth. Values are rounded to four significant digits. Amplitudes below 0.0001% display as <0.0001%. That is a display floor only, since the field in a semi-infinite conductor is mathematically never exactly zero.

Built-in presets

Preset Mode Inputs Result
Copper model · 1 MHz Simple 1 MHz, 58 MS/m, μr=1\mu_r = 1 δ=66.09 μm\delta = 66.09\ \mu\text{m}
Copper model · 100 MHz Simple 100 MHz, 58 MS/m, μr=1\mu_r = 1 δ=6.609 μm\delta = 6.609\ \mu\text{m}
Aluminum model · 35 MS/m Advanced 1 MHz, 35 MS/m, μr=1\mu_r = 1, x=0.1 mmx = 0.1\ \text{mm} δ=85.07 μm\delta = 85.07\ \mu\text{m}, Rs=0.3359 mΩ/□R_s = 0.3359\ \text{m}\Omega/\square, amplitude 30.87%

Worked example: brass at 10 MHz

Select Advanced mode and enter f=10 MHzf = 10\ \text{MHz}, σ=15 MS/m\sigma = 15\ \text{MS/m}, μr=1\mu_r = 1, x=0.05 mmx = 0.05\ \text{mm}.

δ=1π⋅107⋅1.25664×10−6⋅1.5×107≈41.09 μm\delta = \frac{1}{\sqrt{\pi \cdot 10^{7} \cdot 1.25664\times10^{-6} \cdot 1.5\times10^{7}}} \approx 41.09\ \mu\text{m}
Rs=1σδ=1(1.5×107)(41.09×10−6)≈1.622 mΩ/□R_s = \frac{1}{\sigma\delta} = \frac{1}{(1.5\times10^{7})(41.09\times10^{-6})} \approx 1.622\ \text{m}\Omega/\square
∣J(50 μm)∣∣J(0)∣=e−50/41.09≈29.62%\frac{|J(50\ \mu\text{m})|}{|J(0)|} = e^{-50/41.09} \approx 29.62\%

Reading the visualizer

The SVG plot shows ∣J(x)∣/∣J(0)∣|J(x)|/|J(0)| over a fixed window of the first 250 µm. To avoid aliasing when δ\delta is only a few micrometres, sampling combines a uniform 200-point physical grid with dense 0.1δ0.1\delta sub-sampling out to 40δ40\delta. A dashed vertical line and dot mark x=δx = \delta (36.8% amplitude). If δ>250 μm\delta > 250\ \mu\text{m} the marker falls outside the window and an explicit label says so. In Advanced mode, a second probe dot marks your chosen observation depth. The plot supports zoom and pan, a Reset View button, Copy Summary to clipboard, and Print/PDF export.

All calculations run in your browser in 64-bit IEEE 754 floating point. Nothing is sent to a server.

Skin Effect Penetration in Copper and RF Conductors

Why δ\delta is a decay constant, not a cutoff

The skin depth is the depth at which the current density has fallen to 1/e≈36.79%1/e \approx 36.79\% of its surface value. Current does not stop there. It continues to decay smoothly, and a portion of it flows at every depth. The table below shows what that exponential implies.

Depth Current density e−x/δe^{-x/\delta} Power-density factor e−2x/δe^{-2x/\delta} Attenuation (dB, amplitude) Fraction of total current inside depth 1−e−x/δ1 - e^{-x/\delta}
00 100% 100% 0 0%
δ\delta 36.79% 13.53% 8.686 63.21%
2δ2\delta 13.53% 1.832% 17.37 86.47%
3δ3\delta 4.979% 0.2479% 26.06 95.02%
4δ4\delta 1.832% 0.0335% 34.74 98.17%
5δ5\delta 0.6738% 0.0045% 43.43 99.33%

Two practical thresholds follow:

  • 63% of the current flows within one δ\delta of the surface, which is why δ\delta is a good first-order estimate of the "effective" conducting layer.
  • Beyond 5δ5\delta, more than 99% of the total current is already enclosed, so a conductor thicker than about 5δ5\delta behaves essentially like a semi-infinite slab and extra thickness adds no meaningful conduction.

Note that the 99% figure refers to the cumulative current carried, not to the field amplitude at 5δ5\delta, which is still 0.67% of the surface value.

Skin depth and surface resistance of annealed copper

The table uses σ=58 MS/m\sigma = 58\ \text{MS/m}, μr=1\mu_r = 1.

Frequency Skin depth δ\delta Surface resistance RsR_s
50 Hz 9.346 mm 0.001845 mΩ/□
60 Hz 8.532 mm 0.002021 mΩ/□
1 kHz 2.090 mm 0.008250 mΩ/□
100 kHz 209.0 µm 0.08250 mΩ/□
1 MHz 66.09 µm 0.2609 mΩ/□
10 MHz 20.90 µm 0.8250 mΩ/□
100 MHz 6.609 µm 2.609 mΩ/□
1 GHz 2.090 µm 8.250 mΩ/□
10 GHz 0.6609 µm 26.09 mΩ/□

At mains frequencies the skin depth (about 8.5–9.3 mm) is comparable to the radius of large busbars and heavy cable conductors, so skin effect starts to matter for very large power conductors. Through the audio range it is still millimetric. From a few hundred kHz upward it falls below typical PCB copper weights, and above 100 MHz it is a few micrometres, thinner than the roughness of standard electrodeposited foil.

Effect of temperature

The calculator does not adjust conductivity for temperature. Enter the effective σ\sigma at your operating temperature. Copper's resistivity rises by roughly 0.393% per °C near room temperature, so at 100 °C the conductivity is about 44 MS/m and δ\delta at 1 MHz grows from 66.09 µm to roughly 75.8 µm, about 15% deeper. For hot power electronics, entering a derated σ\sigma in Advanced mode is the correct approach.

Planar Surface Resistance and High-Frequency Attenuation

Because current is confined to a layer of effective thickness δ\delta, the conductor presents a resistance per square of

Rs=1σδ=πfμσR_s = \frac{1}{\sigma\delta} = \sqrt{\frac{\pi f \mu}{\sigma}}

RsR_s has units of ohms per square (Ω/□) and is displayed in mΩ/□. The resistance of a flat strip carrying current along its length is then R=Rs⋅ℓ/wR = R_s \cdot \ell / w for length ℓ\ell and width ww, valid when the thickness exceeds roughly 5δ5\delta and the current is uniform across the width. Because Rs∝fR_s \propto \sqrt{f} and δ∝1/f\delta \propto 1/\sqrt{f}, surface resistance rises as the square root of frequency. Conductor loss in a transmission line therefore scales as f\sqrt{f} until dielectric loss, which scales roughly with ff, takes over.

RsR_s is not the resistance of a wire

The calculator gives a planar, one-dimensional result. It does not give Rac/RdcR_{ac}/R_{dc} for a real conductor. For a round wire of radius aa with a≫δa \gg \delta, a common engineering approximation is

RacRdc≈a2δ\frac{R_{ac}}{R_{dc}} \approx \frac{a}{2\delta}

For example, a 1 mm radius copper wire at 1 MHz has a/2δ≈7.6a/2\delta \approx 7.6. That estimate is a useful sanity check, but accurate values require Bessel-function solutions, and real windings and adjacent conductors add proximity effect, which can dominate in transformers and inductors. These effects are outside the calculator. Use δ\delta here to choose strand diameters (for Litz wire, strands are commonly kept at or below about 2δ2\delta at the highest frequency of interest) and to check whether a given trace or foil is thicker than 5δ5\delta.

Conductivity and Permeability of Common Metals

Skin depth at 1 MHz for representative materials. Conductivities are nominal handbook values; real alloys vary with composition, temper and temperature, so enter your own measured σ\sigma when it matters.

Material σ\sigma (MS/m) % IACS μr\mu_r δ\delta at 1 MHz
Silver 63 108.6% 1 63.41 µm
Copper (annealed) 58 100% 1 66.09 µm
Gold 41 70.7% 1 78.60 µm
Aluminum 35 60.3% 1 85.07 µm
Brass (typical) 15 25.9% 1 129.9 µm
Nickel 14.3 24.7% ≈100 (indicative; highly variable) ≈13.3 µm (133.1 µm if μr=1\mu_r = 1)
Stainless steel 304 1.4 2.4% ≈1 (annealed, non-magnetic) 425.4 µm

% IACS (International Annealed Copper Standard) expresses conductivity relative to 58 MS/m.

Magnetic materials: handle μr\mu_r with care

When μr≠1\mu_r \neq 1, the scalar model is only an approximation. Real magnetic materials (iron, nickel, high-permeability alloys, ferrites) have a permeability that depends strongly on frequency and field level. It is a complex quantity μ=μ′−jμ′′\mu = \mu' - j\mu'', it saturates at high flux density, and domain-wall relaxation causes the effective permeability to collapse well below the DC or low-frequency datasheet value as frequency rises. The calculator treats μr\mu_r strictly as a real scalar. Entering a static or 1 kHz permeability into an RF calculation will therefore underestimate the true penetration depth, sometimes by an order of magnitude. For magnetic conductors, use μr\mu_r measured at the operating frequency, or treat the output as a lower bound on δ\delta.

The nickel row illustrates the problem. At 1 MHz with μr=1\mu_r = 1 the formula gives 133.1 µm, while a nominal μr=100\mu_r = 100 gives 13.3 µm. The truth at that frequency depends on the specific nickel grade, processing and bias, and is rarely either number.

Plating, Roughness, and Round-Wire Resistance

The calculator models a homogeneous semi-infinite slab. Several real-world effects sit on top of that model.

Plating on RF PCB traces. When a thin plating layer is thinner than δ\delta at the operating frequency, current spreads into the layer beneath it, so the underlying metal sets the loss. If the plating is much thicker than 5δ5\delta, the plating dominates. Copper's δ\delta at 1 GHz is 2.090 µm. Gold at 1 GHz has δ≈2.5 μm\delta \approx 2.5\ \mu\text{m} (from the 1 MHz value scaled by 1/10001/\sqrt{1000}), so a flash of 0.05–0.1 µm immersion gold in an ENIG finish is far thinner than δ\delta and the current effectively sees the nickel underneath. Nickel is both less conductive than copper and potentially magnetic, so it can add measurable loss at microwave frequencies. Evaluate each layer separately with the calculator, and use a multilayer model for quantitative results. This tool does not compute multi-layer attenuation.

Surface roughness. When RMS roughness approaches δ\delta, the current path lengthens and conductor loss rises above the smooth-surface prediction, by up to roughly a factor of two in the Hammerstad–Jensen model and more in the Huray "snowball" model. At 10 GHz, copper's δ\delta is 0.66 µm, smaller than typical standard-foil roughness. The calculator does not apply any roughness correction.

Shielding. Observation depth in a semi-infinite slab is not shielding effectiveness. Real shielding effectiveness combines reflection loss, absorption loss (which is where e−x/δe^{-x/\delta} contributes, as 8.686 t/δ8.686\,t/\delta dB for thickness tt), multiple reflections in thin foils, and aperture and seam leakage.

Model Limits and Exclusions

To keep results interpretable, the calculator deliberately does not:

  • model biological tissue or "skin" penetration of any kind; it is strictly conductor electromagnetics;
  • solve lossy dielectrics or full-wave problems where ωϵ\omega\epsilon is comparable to σ\sigma;
  • compute total round-wire AC resistance, Rac/RdcR_{ac}/R_{dc} ratios, Bessel-function (Kelvin) solutions, proximity effect, or return-conductor geometry;
  • apply any surface-roughness power-loss model;
  • compute multi-layer plating attenuation;
  • compute total electromagnetic shielding effectiveness, thin-foil transmission or aperture and cavity effects;
  • correct conductivity for temperature.

Frequently Asked Questions

What is the skin depth of copper at 1 MHz?

With σ=58 MS/m\sigma = 58\ \text{MS/m} and μr=1\mu_r = 1, the skin depth is 66.09 µm. At 100 MHz it is 6.609 µm, and at 1 GHz it is 2.090 µm.

How thick should a conductor be to avoid skin-effect penalties?

At least 3δ3\delta captures 95% of the current and 5δ5\delta captures more than 99%. Beyond that, extra thickness does not reduce the high-frequency resistance. Below that, the resistance is intermediate between the DC and fully skin-limited values.

Is the skin depth the point where current stops?

No. δ\delta is where the current density has decayed to 36.79% of its surface value (about −8.69-8.69 dB in amplitude). The decay continues exponentially without a sharp edge.

How do I enter conductivity in S/m?

The conductivity field takes MS/m. Divide S/m by 10610^6. For example, 3.5×107 S/m3.5 \times 10^7\ \text{S/m} is 35 MS/m. Resistivity ρ\rho in Ω·m converts as σ=1/ρ\sigma = 1/\rho.

Why did the frequency change when I switched units?

By design, switching the unit reinterprets the number already typed. 1 with kHz selected means 1 kHz. Retype the value if you intended a conversion.

Calculation Methodology Documented

Read the formula definitions, supported input ranges, and limitations before using this estimate.

Review Methodology
Debjeet Bhowmick
Author Debjeet Bhowmick AWS Certified Solutions Architect • Cloud & DevOps Consultant

AWS Certified Solutions Architect Professional and Senior Cloud & DevOps Consultant with over 14 years of hands-on expertise architecting resilient cloud infrastructure across AWS, GCP, and Azure. Specializes in infrastructure as code, continuous delivery automation, and telemetry across Terraform, Ansible, Docker, Kubernetes, ELK, Python, and SQL. Creator of OrangeCalc, delivering client-side high-precision computational tools.