How to use the calculator
Simple mode is the default. It always models a bare, single-ended surface microstrip and always calculates impedance from width. You supply four numbers: trace width , dielectric clearance , copper thickness , and relative permittivity . The main result is the estimated single-ended impedance, and the cross-section also shows an isolated-trace delay per unit length. Any choices hidden under Advanced have no effect on a Simple calculation.
Advanced mode adds three choices:
- Geometry: surface microstrip or symmetric stripline.
- Signal type: single-ended or differential pair (two equal-width, edge-coupled traces).
- Task: impedance from width, or width for a target impedance.
Both tasks work for both geometries and both signal types. Two further inputs appear in Advanced mode: the edge-to-edge pair gap (active only for differential pairs) and the trace length (which affects only total one-way delay). During width solving, the target impedance replaces the width input. For a differential pair, the target is the full pair differential impedance, not the impedance of one conductor.
Dimensions can be entered in mm (default) or mil, using the exact conversion 1 mil = 0.0254 mm. Switching units converts every valid dimensional field, including hidden ones, so the geometry stays the same. Typed values may be decimals or scientific notation and need not land on a slider step. Empty, malformed, nonfinite, or out-of-bounds active values are rejected with a message on the offending field, and results show an em dash until the input is fixed.
Defaults and input bounds
| Input | Default | Accepted range | Used for |
|---|---|---|---|
| Trace width | 0.33 mm | 0.001–15 mm | Impedance-from-width task |
| Dielectric clearance | 0.2 mm | 0.01–5 mm | All calculations |
| Copper thickness | 0.035 mm | 0–0.35 mm | All calculations |
| Relative permittivity | 4.2 | 2–10 | All calculations |
| Pair gap | 0.2 mm | 0.001–50 mm | Advanced differential |
| Target impedance | 50 Ω | 10–300 Ω | Advanced width solving |
| Trace length | 100 mm | 0–10000 mm | Advanced one-way delay |
These defaults are illustrative. A relative permittivity of 4.2 is not a universal FR-4 value, and 0.035 mm is not a universal conversion from copper weight to finished trace thickness. Use the numbers from your own stackup.
Geometry guards
Passing each field's range is not enough. The combined geometry must also satisfy:
- for differential pairs,
Zero copper thickness is accepted as a theoretical thin-trace limit, not a manufacturable trace. These limits stop the formulas from being used in extreme extrapolation. They are not certified accuracy ranges, error bounds, or manufacturing rules.
Defining the geometry
Different tools may use different height and spacing conventions. Matching the definitions is essential when entering a stackup or comparing results.
| Symbol | Meaning |
|---|---|
| Finished width of each trace | |
| Dielectric clearance from the copper face to the reference plane, excluding copper thickness | |
| Finished copper thickness | |
| Edge-to-edge spacing between the two traces of a pair (not center-to-center pitch) | |
| Full separation between the two reference planes of a symmetric stripline |
Surface microstrip here means a bare trace with air above, a dielectric below, and a continuous return plane under the dielectric.
Symmetric stripline means the trace is centered between two return planes with equal dielectric clearance above and below the copper. The plane-to-plane separation is
So in stripline is neither , nor half of , nor the total board thickness. If your stackup lists a core and prepreg thickness, work out the clearance from the copper face to each plane before typing it in.
The equations behind the numbers
The calculator implements preliminary quasi-static closed-form approximations. All lengths in a single equation must use the same unit, and is the natural logarithm. The approach follows the IPC-style estimates in Analog Devices tutorial MT-094 (equations 3 and 7), the differential microstrip factor discussed in Texas Instruments application note SNLA187 (section 5.1), and a differential stripline convention based on described in Gem Circuits' stripline notes.
Isolated-trace impedance
For a bare surface microstrip:
For a symmetric stripline:
Single-ended mode reports this .
Differential pairs
For two equal, edge-coupled traces, the isolated-trace value is scaled by a coupling factor.
Differential microstrip:
Differential symmetric stripline:
The stripline exponent deliberately uses the full plane separation , not . Substituting for gives a different answer, and other published conventions exist, so compare like with like when checking against another tool.
For pairs, is the isolated-trace baseline for the same cross-section. It is not the single-ended input impedance of an excited coupled pair. The calculator also reports an odd-mode estimate:
It does not calculate even-mode or common-mode impedance.
Why geometry moves impedance the way it does
The implemented equations show how individual inputs affect the estimate when the other inputs stay fixed:
- Wider trace makes larger, so the log shrinks and impedance falls.
- Thicker copper lowers the microstrip estimate through the same denominator. In stripline, changing also changes , so both parts of the equation must be evaluated.
- Larger clearance raises the isolated-trace baseline, because the trace sits farther from its return path. In pair mode it also changes the coupling factor.
- Higher lowers impedance through the square-root term.
- Closer pair spacing makes the exponential term larger, which lowers below the uncoupled .
Trace length does not appear in any impedance equation. In this uniform model, length affects only delay.
Solving trace width for a target impedance
The common design question is the reverse of the formulas above: what width gives 50 Ω? The calculator inverts the equations directly. Define
- and for microstrip,
- and for stripline,
- for single-ended signaling,
- for differential microstrip,
- for differential stripline.
Then the width is
During the solve, , , , geometry, signal type, and any active gap stay fixed. The calculator does not solve for spacing or optimize the stackup. If you need a different gap for a differential target, change and solve again.
A target inside the 10–300 Ω input range is not necessarily reachable for the chosen geometry. A solved width must satisfy both 0.001–15 mm and . If it does not, you get a field-linked error rather than a clipped width. The impedance shown next to the solved width is evaluated at the unrounded width, so retyping the rounded display value can shift the result by a small amount.
Worked examples
Every number below uses mm, mm, and unless stated, and each can be reproduced in the calculator.
Single-ended microstrip
With mm:
This is the Simple-mode default and the first preset. In mil, the same geometry is about 12.992 mil wide over 7.874 mil of dielectric with 1.378 mil copper.
Solving a 50 Ω microstrip width
Using the same stackup and a 50 Ω target, the solver returns mm (about 0.3394854 mm unrounded), which is . The model impedance at that width is 50.00 Ω. The default 0.33 mm sits about 0.92 Ω above target, which is why a 50 Ω request lands slightly wider.
Differential microstrip
Keep mm and set the gap to mm:
The isolated baseline stays 50.92 Ω and the odd-mode estimate is 41.56 Ω. Notice this pair is nowhere near 100 Ω. The hidden target in this preset is irrelevant to an impedance-from-width calculation.
To aim for 100 Ω differential in the same stackup with mm, switch to the width task. The solver gives mm (), with an isolated baseline of about 61.3 Ω. Widening the gap to mm gives mm for the same 100 Ω target. The larger gap weakens coupling, so a wider trace is needed to lower the isolated baseline and retain the same full-pair impedance in this model.
Symmetric stripline
With mm, the plane separation is mm:
Solving for 50 Ω in this stripline gives mm (). A differential stripline with mm and mm has a baseline of about 49.00 Ω and a of about 89.04 Ω, using in the coupling term.
How sensitive is the answer?
Starting from the 50.92 Ω microstrip, one variable changed at a time:
| Change | Resulting |
|---|---|
| = 0.30 mm | 53.99 Ω |
| = 0.36 mm | 48.08 Ω |
| = 0.18 mm | 47.05 Ω |
| = 0.22 mm | 54.42 Ω |
| = 3.8 | 52.84 Ω |
| = 4.6 | 49.20 Ω |
A 10% shift in dielectric thickness moves the result by about 3–4 Ω, and a 0.03 mm width change moves it by about 3 Ω. This is why the inputs should come from your real stackup, not from typical values. It also shows why a fabricator's tolerance on dielectric thickness, etch, and material matters as much as the formula.
Propagation delay
Delay uses a separate isolated-trace effective-permittivity approximation:
With the exact vacuum speed of light mm/ns:
For :
| Geometry | Delay rate | One-way delay, 100 mm | |
|---|---|---|---|
| Surface microstrip | 2.665 | 5.445 ps/mm | 0.545 ns |
| Symmetric stripline | 4.200 | 6.836 ps/mm | 0.684 ns |
The stripline is slower because its field lies entirely in the dielectric, while a microstrip field is partly in air. In mil mode the rate is the ps/mm value multiplied by 0.0254, so the microstrip example is about 0.138 ps/mil.
Treat this as a one-way flight-time estimate for an isolated trace. Its delay rate depends on the geometry choice and supplied permittivity, rather than on the calculated impedance. It does not refine modal velocity for coupled pairs, has no frequency input or dispersion model, and excludes drivers, receivers, connectors, and other system delays. Even and odd modes in a real coupled pair can travel at different speeds, which this tool does not capture.
Reading the results and warnings
Advanced results can include the model impedance at the solved width, the isolated baseline and odd-mode estimate for pairs, the delay-model , the delay rate, and the one-way delay. Impedance is shown to two decimals, widths to 0.0001 mm (or 0.001 mil), and delay to three decimals. Those digits reflect arithmetic precision only. They say nothing about physical uncertainty or fabrication tolerance.
Two advisories can appear:
- Differential pair advisory. Shown for every valid differential calculation. It reminds you that is the isolated baseline, is the odd-mode estimate, delay does not model pair velocity, and coupling should be confirmed with the fabricator's field solver.
- Microstrip baseline warning. Shown when the isolated microstrip , rounded to nine decimals, is below 50 Ω or above 100 Ω, for single-ended and differential microstrip alike. It signals reduced reliability of this simple approximation outside that range. It is neither an error bound nor an acceptance test, and the absence of a warning does not mean the result is accurate. It does not apply to stripline.
What this calculator does not model
The supported structure is a bare, uniform microstrip or a centered symmetric stripline, with rectangular traces over large continuous reference planes. The following are outside the model:
- Solder mask or coated microstrip, and embedded microstrip
- Coplanar structures, asymmetric stripline, and broadside-coupled pairs
- Vias and differential vias, bends, connectors, and other discontinuities
- Copper roughness, etch taper, and trapezoidal cross-sections
- Frequency-dependent loss and dispersion
- Fabrication tolerance and statistical yield
- DC resistance, current capacity, and thermal trace sizing
- Driver output impedance, termination, and matching networks
Solder mask, in particular, usually lowers the impedance of an outer-layer trace, so a bare-microstrip estimate can read high for a masked board. The calculator does not choose a laminate, look up manufacturer material data, or supply fabricator stackups, and it makes no claim of equivalence with any specific fabricator or EDA tool. Matching a formula's output to another tool shows that both implement similar math. It does not prove that your manufactured board will measure the same.
Using the estimate in a real design
A reasonable workflow:
- Take , , and from your fabricator's proposed stackup, not from general typical values.
- Solve width for your target to get a starting point, then check that is practical for your routing density.
- For differential pairs, pick a gap, solve width, and check the result against the fabricator's field solver, including its treatment of coupling.
- Agree the target impedance, layer, tolerance and any required width adjustments with the fabricator, and ask about coupon testing for critical interfaces.
The 50 Ω figure itself is a convention, not a law of nature. It is common in RF and many single-ended interfaces, while 90 Ω and 100 Ω differential are typical targets for several high-speed serial standards. Check the specification for your interface for the actual requirement.
Other tools on the page
- Cross-section. A reactive SVG shows one trace or two, the return plane(s), and the dimensions , , , , and where they apply. Thin copper is exaggerated for visibility, so it is not a manufacturing drawing, and it does not display an electromagnetic field. Zoom, pan, and Reset View change only the viewport.
- Copy copies the active inputs, units, applicable results, and model cautions. It is disabled while inputs are invalid.
- Export opens your browser's print or save-as-PDF dialog.
- Reset restores the baseline example in mm, Simple mode, microstrip, single-ended, impedance from width.
- Split / Stack changes the workspace layout.
- Presets. Four presets restore complete configurations: the microstrip example, differential microstrip, symmetric stripline, and a 50 Ω microstrip width solve.
There is no CSV download and no dedicated share-URL feature. Calculations run locally in the browser using deterministic JavaScript floating-point arithmetic, so no server is needed to compute a result.
Frequently asked questions
What does this calculator compute?
It estimates characteristic impedance for bare surface microstrip and symmetric stripline, including edge-coupled differential pairs. It can also solve trace width for a target impedance and estimate one-way delay for an isolated trace.
Can I use it for an FR-4 board?
Yes, if you supply the dielectric constant and thicknesses from your stackup. The calculator has no built-in FR-4 material. The default is only an example, and real laminate values vary with resin content, glass style, and frequency.
How do I find the trace width for 50 Ω?
Switch to Advanced mode, choose the geometry and single-ended signaling, select "Width for target impedance," and set the target to 50 Ω. With the default microstrip stackup, the solver returns about 0.3395 mm.
Is the differential target the impedance of each trace?
No. In differential mode the target is the full pair impedance . The per-conductor odd-mode estimate is .
Why is my differential pair far from 100 Ω with the preset values?
The differential microstrip preset uses mm and mm, which gives 83.12 Ω. Its hidden 100 Ω target only applies to the width-solving task. Switch tasks or adjust width and gap to approach 100 Ω.
Why does solving fail for some targets?
The solved width must fall within 0.001–15 mm and satisfy . A target outside what the chosen geometry can reach under those limits returns an error rather than a clipped width. Changing , , or geometry changes what is reachable.
Does trace length change impedance?
Not in this model. Length scales only the total one-way delay.
How accurate is it?
It is a preliminary closed-form estimate, not a field solver, and it makes no claim of error bounds. Solder mask, copper roughness, etch shape, frequency effects, and fabrication tolerance can all move a real board away from the calculated number. Confirm critical designs with your fabricator's field solver and verified stackup.
Does the delay result include frequency effects?
No. The delay model has no frequency input or dispersion, and it describes an isolated trace even in pair mode.
Does it work with mils?
Yes. Select mil in the header. All dimensional fields convert using 1 mil = 0.0254 mm, and delay rates are reported in ps/mil.
Read the formula definitions, supported input ranges, and limitations before using this estimate.