Home Calculators Categories Category: Science & Engineering

PCB impedance calculator

Enter a trace width, dielectric clearance, copper thickness, and relative permittivity to get a preliminary characteristic impedance for a surface microstrip, or switch to Advanced mode for symmetric stripline, edge-coupled differential pairs, and width solving for a target such as 50 Ω or 100 Ω differential. The calculator also estimates isolated-trace propagation delay. It uses published closed-form approximations, runs locally in your browser, and is meant for early stackup planning rather than for signing off a controlled-impedance board.

Input

Bare surface microstrip · continuous return plane · preliminary closed-form estimate. h is dielectric clearance, excluding copper.

Illustrative geometry only; replace with your fabricator’s finished stackup.
Finished trace width. Tool limit: 0.1h–3h. Width is solved instead when Calculate is set to Width for target impedance.
mm

Finished trace width. Tool limit: 0.1h–3h. Width is solved instead when Calculate is set to Width for target impedance.

Copper face to reference-plane dielectric clearance, not total PCB thickness. Symmetric stripline has this clearance above and below the copper.
mm

Copper face to reference-plane dielectric clearance, not total PCB thickness. Symmetric stripline has this clearance above and below the copper.

Finished copper thickness, not copper weight. At most 0.25h in this model; zero is the theoretical thin-trace limit.
mm

Finished copper thickness, not copper weight. At most 0.25h in this model; zero is the theoretical thin-trace limit.

Use the laminate’s design dielectric constant for the intended frequency. Example 4.2 is not universal FR-4.

Use the laminate’s design dielectric constant for the intended frequency. Example 4.2 is not universal FR-4.

Visual
PCB transmission line cross-sectionTrace width w, dielectric clearance h, copper thickness t and, for differential pairs, edge gap s. Stripline has two return planes separated by B equals 2h plus t. Copper thickness may be exaggerated for visibility.
Output
Estimated single-ended impedance
—

Numerical estimate, not a fabrication tolerance. Confirm the finished stackup with your fabricator.

How to use the calculator

Simple mode is the default. It always models a bare, single-ended surface microstrip and always calculates impedance from width. You supply four numbers: trace width ww, dielectric clearance hh, copper thickness tt, and relative permittivity εr\varepsilon_r. The main result is the estimated single-ended impedance, and the cross-section also shows an isolated-trace delay per unit length. Any choices hidden under Advanced have no effect on a Simple calculation.

Advanced mode adds three choices:

  • Geometry: surface microstrip or symmetric stripline.
  • Signal type: single-ended or differential pair (two equal-width, edge-coupled traces).
  • Task: impedance from width, or width for a target impedance.

Both tasks work for both geometries and both signal types. Two further inputs appear in Advanced mode: the edge-to-edge pair gap ss (active only for differential pairs) and the trace length (which affects only total one-way delay). During width solving, the target impedance replaces the width input. For a differential pair, the target is the full pair differential impedance, not the impedance of one conductor.

Dimensions can be entered in mm (default) or mil, using the exact conversion 1 mil = 0.0254 mm. Switching units converts every valid dimensional field, including hidden ones, so the geometry stays the same. Typed values may be decimals or scientific notation and need not land on a slider step. Empty, malformed, nonfinite, or out-of-bounds active values are rejected with a message on the offending field, and results show an em dash until the input is fixed.

Defaults and input bounds

Input Default Accepted range Used for
Trace width ww 0.33 mm 0.001–15 mm Impedance-from-width task
Dielectric clearance hh 0.2 mm 0.01–5 mm All calculations
Copper thickness tt 0.035 mm 0–0.35 mm All calculations
Relative permittivity εr\varepsilon_r 4.2 2–10 All calculations
Pair gap ss 0.2 mm 0.001–50 mm Advanced differential
Target impedance 50 Ω 10–300 Ω Advanced width solving
Trace length 100 mm 0–10000 mm Advanced one-way delay

These defaults are illustrative. A relative permittivity of 4.2 is not a universal FR-4 value, and 0.035 mm is not a universal conversion from copper weight to finished trace thickness. Use the numbers from your own stackup.

Geometry guards

Passing each field's range is not enough. The combined geometry must also satisfy:

  • 0.1≤w/h≤30.1 \le w/h \le 3
  • 0≤t/h≤0.250 \le t/h \le 0.25
  • for differential pairs, 0.1≤s/h≤100.1 \le s/h \le 10

Zero copper thickness is accepted as a theoretical thin-trace limit, not a manufacturable trace. These limits stop the formulas from being used in extreme extrapolation. They are not certified accuracy ranges, error bounds, or manufacturing rules.

Defining the geometry

Different tools may use different height and spacing conventions. Matching the definitions is essential when entering a stackup or comparing results.

Symbol Meaning
ww Finished width of each trace
hh Dielectric clearance from the copper face to the reference plane, excluding copper thickness
tt Finished copper thickness
ss Edge-to-edge spacing between the two traces of a pair (not center-to-center pitch)
BB Full separation between the two reference planes of a symmetric stripline

Surface microstrip here means a bare trace with air above, a dielectric below, and a continuous return plane under the dielectric.

Symmetric stripline means the trace is centered between two return planes with equal dielectric clearance hh above and below the copper. The plane-to-plane separation is

B=2h+tB = 2h + t

So hh in stripline is neither BB, nor half of BB, nor the total board thickness. If your stackup lists a core and prepreg thickness, work out the clearance from the copper face to each plane before typing it in.

The equations behind the numbers

The calculator implements preliminary quasi-static closed-form approximations. All lengths in a single equation must use the same unit, and ln⁡\ln is the natural logarithm. The approach follows the IPC-style estimates in Analog Devices tutorial MT-094 (equations 3 and 7), the differential microstrip factor discussed in Texas Instruments application note SNLA187 (section 5.1), and a differential stripline convention based on s/(2h+t)s/(2h+t) described in Gem Circuits' stripline notes.

Isolated-trace impedance

For a bare surface microstrip:

Z0=87εr+1.41 ln⁡ ⁣(5.98 h0.8 w+t)Z_0 = \frac{87}{\sqrt{\varepsilon_r + 1.41}}\,\ln\!\left(\frac{5.98\,h}{0.8\,w + t}\right)

For a symmetric stripline:

Z0=60εr ln⁡ ⁣(1.9 B0.8 w+t)Z_0 = \frac{60}{\sqrt{\varepsilon_r}}\,\ln\!\left(\frac{1.9\,B}{0.8\,w + t}\right)

Single-ended mode reports this Z0Z_0.

Differential pairs

For two equal, edge-coupled traces, the isolated-trace value is scaled by a coupling factor.

Differential microstrip:

Zdiff=2Z0[1−0.48 e−0.96 s/h]Z_{diff} = 2Z_0\left[1 - 0.48\,e^{-0.96\,s/h}\right]

Differential symmetric stripline:

Zdiff=2Z0[1−0.347 e−2.9 s/B]Z_{diff} = 2Z_0\left[1 - 0.347\,e^{-2.9\,s/B}\right]

The stripline exponent deliberately uses the full plane separation B=2h+tB = 2h + t, not hh. Substituting hh for BB gives a different answer, and other published conventions exist, so compare like with like when checking against another tool.

For pairs, Z0Z_0 is the isolated-trace baseline for the same cross-section. It is not the single-ended input impedance of an excited coupled pair. The calculator also reports an odd-mode estimate:

Zodd=Zdiff2Z_{odd} = \frac{Z_{diff}}{2}

It does not calculate even-mode or common-mode impedance.

Why geometry moves impedance the way it does

The implemented equations show how individual inputs affect the estimate when the other inputs stay fixed:

  • Wider trace makes 0.8w+t0.8w + t larger, so the log shrinks and impedance falls.
  • Thicker copper lowers the microstrip estimate through the same denominator. In stripline, changing tt also changes B=2h+tB = 2h+t, so both parts of the equation must be evaluated.
  • Larger clearance hh raises the isolated-trace baseline, because the trace sits farther from its return path. In pair mode it also changes the coupling factor.
  • Higher εr\varepsilon_r lowers impedance through the square-root term.
  • Closer pair spacing makes the exponential term larger, which lowers ZdiffZ_{diff} below the uncoupled 2Z02Z_0.

Trace length does not appear in any impedance equation. In this uniform model, length affects only delay.

Solving trace width for a target impedance

The common design question is the reverse of the formulas above: what width gives 50 Ω? The calculator inverts the equations directly. Define

  • a=87/εr+1.41a = 87/\sqrt{\varepsilon_r + 1.41} and N=5.98hN = 5.98h for microstrip,
  • a=60/εra = 60/\sqrt{\varepsilon_r} and N=1.9BN = 1.9B for stripline,
  • F=1F = 1 for single-ended signaling,
  • F=2[1−0.48 e−0.96s/h]F = 2\left[1 - 0.48\,e^{-0.96s/h}\right] for differential microstrip,
  • F=2[1−0.347 e−2.9s/B]F = 2\left[1 - 0.347\,e^{-2.9s/B}\right] for differential stripline.

Then the width is

w=N e−Ztarget/(Fa)−t0.8w = \frac{N\,e^{-Z_{target}/(F a)} - t}{0.8}

During the solve, hh, tt, εr\varepsilon_r, geometry, signal type, and any active gap stay fixed. The calculator does not solve for spacing or optimize the stackup. If you need a different gap for a differential target, change ss and solve again.

A target inside the 10–300 Ω input range is not necessarily reachable for the chosen geometry. A solved width must satisfy both 0.001–15 mm and 0.1≤w/h≤30.1 \le w/h \le 3. If it does not, you get a field-linked error rather than a clipped width. The impedance shown next to the solved width is evaluated at the unrounded width, so retyping the rounded display value can shift the result by a small amount.

Worked examples

Every number below uses h=0.2h = 0.2 mm, t=0.035t = 0.035 mm, and εr=4.2\varepsilon_r = 4.2 unless stated, and each can be reproduced in the calculator.

Single-ended microstrip

With w=0.33w = 0.33 mm:

Z0=875.61ln⁡ ⁣(5.98×0.20.8×0.33+0.035)Z_0 = \frac{87}{\sqrt{5.61}}\ln\!\left(\frac{5.98 \times 0.2}{0.8 \times 0.33 + 0.035}\right)
Z0≈36.73×ln⁡(4.000)≈50.92 ΩZ_0 \approx 36.73 \times \ln(4.000) \approx 50.92\ \Omega

This is the Simple-mode default and the first preset. In mil, the same geometry is about 12.992 mil wide over 7.874 mil of dielectric with 1.378 mil copper.

Solving a 50 Ω microstrip width

Using the same stackup and a 50 Ω target, the solver returns w≈0.3395w \approx 0.3395 mm (about 0.3394854 mm unrounded), which is w/h≈1.70w/h \approx 1.70. The model impedance at that width is 50.00 Ω. The default 0.33 mm sits about 0.92 Ω above target, which is why a 50 Ω request lands slightly wider.

Differential microstrip

Keep w=0.33w = 0.33 mm and set the gap to s=0.2s = 0.2 mm:

Zdiff=2(50.92)[1−0.48 e−0.96]≈83.12 ΩZ_{diff} = 2(50.92)\left[1 - 0.48\,e^{-0.96}\right] \approx 83.12\ \Omega

The isolated baseline stays 50.92 Ω and the odd-mode estimate is 41.56 Ω. Notice this pair is nowhere near 100 Ω. The hidden target in this preset is irrelevant to an impedance-from-width calculation.

To aim for 100 Ω differential in the same stackup with s=0.2s = 0.2 mm, switch to the width task. The solver gives w≈0.2383w \approx 0.2383 mm (w/h≈1.19w/h \approx 1.19), with an isolated baseline of about 61.3 Ω. Widening the gap to s=0.3s = 0.3 mm gives w≈0.2781w \approx 0.2781 mm for the same 100 Ω target. The larger gap weakens coupling, so a wider trace is needed to lower the isolated baseline and retain the same full-pair impedance in this model.

Symmetric stripline

With w=0.18w = 0.18 mm, the plane separation is B=2(0.2)+0.035=0.435B = 2(0.2) + 0.035 = 0.435 mm:

Z0=604.2ln⁡ ⁣(1.9×0.4350.8×0.18+0.035)≈29.28×1.530≈44.79 ΩZ_0 = \frac{60}{\sqrt{4.2}}\ln\!\left(\frac{1.9 \times 0.435}{0.8 \times 0.18 + 0.035}\right) \approx 29.28 \times 1.530 \approx 44.79\ \Omega

Solving for 50 Ω in this stripline gives w≈0.1435w \approx 0.1435 mm (w/h≈0.72w/h \approx 0.72). A differential stripline with w=0.15w = 0.15 mm and s=0.2s = 0.2 mm has a baseline of about 49.00 Ω and a ZdiffZ_{diff} of about 89.04 Ω, using s/Bs/B in the coupling term.

How sensitive is the answer?

Starting from the 50.92 Ω microstrip, one variable changed at a time:

Change Resulting Z0Z_0
ww = 0.30 mm 53.99 Ω
ww = 0.36 mm 48.08 Ω
hh = 0.18 mm 47.05 Ω
hh = 0.22 mm 54.42 Ω
εr\varepsilon_r = 3.8 52.84 Ω
εr\varepsilon_r = 4.6 49.20 Ω

A 10% shift in dielectric thickness moves the result by about 3–4 Ω, and a 0.03 mm width change moves it by about 3 Ω. This is why the inputs should come from your real stackup, not from typical values. It also shows why a fabricator's tolerance on dielectric thickness, etch, and material matters as much as the formula.

Propagation delay

Delay uses a separate isolated-trace effective-permittivity approximation:

εeff=0.475 εr+0.67(microstrip)\varepsilon_{eff} = 0.475\,\varepsilon_r + 0.67 \quad \text{(microstrip)}
εeff=εr(stripline)\varepsilon_{eff} = \varepsilon_r \quad \text{(stripline)}

With the exact vacuum speed of light c=299.792458c = 299.792458 mm/ns:

d=1000εeff299.792458 ps/mmd = \frac{1000\sqrt{\varepsilon_{eff}}}{299.792458}\ \text{ps/mm}
τ=d L1000 ns\tau = \frac{d\,L}{1000}\ \text{ns}

For εr=4.2\varepsilon_r = 4.2:

Geometry εeff\varepsilon_{eff} Delay rate One-way delay, 100 mm
Surface microstrip 2.665 5.445 ps/mm 0.545 ns
Symmetric stripline 4.200 6.836 ps/mm 0.684 ns

The stripline is slower because its field lies entirely in the dielectric, while a microstrip field is partly in air. In mil mode the rate is the ps/mm value multiplied by 0.0254, so the microstrip example is about 0.138 ps/mil.

Treat this as a one-way flight-time estimate for an isolated trace. Its delay rate depends on the geometry choice and supplied permittivity, rather than on the calculated impedance. It does not refine modal velocity for coupled pairs, has no frequency input or dispersion model, and excludes drivers, receivers, connectors, and other system delays. Even and odd modes in a real coupled pair can travel at different speeds, which this tool does not capture.

Reading the results and warnings

Advanced results can include the model impedance at the solved width, the isolated baseline Z0Z_0 and odd-mode estimate for pairs, the delay-model εeff\varepsilon_{eff}, the delay rate, and the one-way delay. Impedance is shown to two decimals, widths to 0.0001 mm (or 0.001 mil), and delay to three decimals. Those digits reflect arithmetic precision only. They say nothing about physical uncertainty or fabrication tolerance.

Two advisories can appear:

  • Differential pair advisory. Shown for every valid differential calculation. It reminds you that Z0Z_0 is the isolated baseline, Zdiff/2Z_{diff}/2 is the odd-mode estimate, delay does not model pair velocity, and coupling should be confirmed with the fabricator's field solver.
  • Microstrip baseline warning. Shown when the isolated microstrip Z0Z_0, rounded to nine decimals, is below 50 Ω or above 100 Ω, for single-ended and differential microstrip alike. It signals reduced reliability of this simple approximation outside that range. It is neither an error bound nor an acceptance test, and the absence of a warning does not mean the result is accurate. It does not apply to stripline.

What this calculator does not model

The supported structure is a bare, uniform microstrip or a centered symmetric stripline, with rectangular traces over large continuous reference planes. The following are outside the model:

  • Solder mask or coated microstrip, and embedded microstrip
  • Coplanar structures, asymmetric stripline, and broadside-coupled pairs
  • Vias and differential vias, bends, connectors, and other discontinuities
  • Copper roughness, etch taper, and trapezoidal cross-sections
  • Frequency-dependent loss and dispersion
  • Fabrication tolerance and statistical yield
  • DC resistance, current capacity, and thermal trace sizing
  • Driver output impedance, termination, and matching networks

Solder mask, in particular, usually lowers the impedance of an outer-layer trace, so a bare-microstrip estimate can read high for a masked board. The calculator does not choose a laminate, look up manufacturer material data, or supply fabricator stackups, and it makes no claim of equivalence with any specific fabricator or EDA tool. Matching a formula's output to another tool shows that both implement similar math. It does not prove that your manufactured board will measure the same.

Using the estimate in a real design

A reasonable workflow:

  1. Take hh, tt, and εr\varepsilon_r from your fabricator's proposed stackup, not from general typical values.
  2. Solve width for your target to get a starting point, then check that w/hw/h is practical for your routing density.
  3. For differential pairs, pick a gap, solve width, and check the result against the fabricator's field solver, including its treatment of coupling.
  4. Agree the target impedance, layer, tolerance and any required width adjustments with the fabricator, and ask about coupon testing for critical interfaces.

The 50 Ω figure itself is a convention, not a law of nature. It is common in RF and many single-ended interfaces, while 90 Ω and 100 Ω differential are typical targets for several high-speed serial standards. Check the specification for your interface for the actual requirement.

Other tools on the page

  • Cross-section. A reactive SVG shows one trace or two, the return plane(s), and the dimensions ww, hh, tt, ss, and BB where they apply. Thin copper is exaggerated for visibility, so it is not a manufacturing drawing, and it does not display an electromagnetic field. Zoom, pan, and Reset View change only the viewport.
  • Copy copies the active inputs, units, applicable results, and model cautions. It is disabled while inputs are invalid.
  • Export opens your browser's print or save-as-PDF dialog.
  • Reset restores the baseline example in mm, Simple mode, microstrip, single-ended, impedance from width.
  • Split / Stack changes the workspace layout.
  • Presets. Four presets restore complete configurations: the microstrip example, differential microstrip, symmetric stripline, and a 50 Ω microstrip width solve.

There is no CSV download and no dedicated share-URL feature. Calculations run locally in the browser using deterministic JavaScript floating-point arithmetic, so no server is needed to compute a result.

Frequently asked questions

What does this calculator compute?

It estimates characteristic impedance for bare surface microstrip and symmetric stripline, including edge-coupled differential pairs. It can also solve trace width for a target impedance and estimate one-way delay for an isolated trace.

Can I use it for an FR-4 board?

Yes, if you supply the dielectric constant and thicknesses from your stackup. The calculator has no built-in FR-4 material. The default εr=4.2\varepsilon_r = 4.2 is only an example, and real laminate values vary with resin content, glass style, and frequency.

How do I find the trace width for 50 Ω?

Switch to Advanced mode, choose the geometry and single-ended signaling, select "Width for target impedance," and set the target to 50 Ω. With the default microstrip stackup, the solver returns about 0.3395 mm.

Is the differential target the impedance of each trace?

No. In differential mode the target is the full pair impedance ZdiffZ_{diff}. The per-conductor odd-mode estimate is Zdiff/2Z_{diff}/2.

Why is my differential pair far from 100 Ω with the preset values?

The differential microstrip preset uses w=0.33w = 0.33 mm and s=0.2s = 0.2 mm, which gives 83.12 Ω. Its hidden 100 Ω target only applies to the width-solving task. Switch tasks or adjust width and gap to approach 100 Ω.

Why does solving fail for some targets?

The solved width must fall within 0.001–15 mm and satisfy 0.1≤w/h≤30.1 \le w/h \le 3. A target outside what the chosen geometry can reach under those limits returns an error rather than a clipped width. Changing hh, εr\varepsilon_r, or geometry changes what is reachable.

Does trace length change impedance?

Not in this model. Length scales only the total one-way delay.

How accurate is it?

It is a preliminary closed-form estimate, not a field solver, and it makes no claim of error bounds. Solder mask, copper roughness, etch shape, frequency effects, and fabrication tolerance can all move a real board away from the calculated number. Confirm critical designs with your fabricator's field solver and verified stackup.

Does the delay result include frequency effects?

No. The delay model has no frequency input or dispersion, and it describes an isolated trace even in pair mode.

Does it work with mils?

Yes. Select mil in the header. All dimensional fields convert using 1 mil = 0.0254 mm, and delay rates are reported in ps/mil.

Calculation Methodology Documented

Read the formula definitions, supported input ranges, and limitations before using this estimate.

Review Methodology
Debjeet Bhowmick
Author Debjeet Bhowmick AWS Certified Solutions Architect • Cloud & DevOps Consultant

AWS Certified Solutions Architect Professional and Senior Cloud & DevOps Consultant with over 14 years of hands-on expertise architecting resilient cloud infrastructure across AWS, GCP, and Azure. Specializes in infrastructure as code, continuous delivery automation, and telemetry across Terraform, Ansible, Docker, Kubernetes, ELK, Python, and SQL. Creator of OrangeCalc, delivering client-side high-precision computational tools.