Home Calculators Categories Category: Science & Engineering

Permeability calculator

This permeability calculator turns saturated-soil test data into hydraulic conductivity KK (length per time), converts between KK and intrinsic permeability kk (area) using fluid density and viscosity, and estimates kk from porosity and grain size. Choose a constant-head or falling-head test, enter your measurements in the units shown, and read the result in both m/s and cm/s. Everything runs in your browser.

Input
Load a worked example. Examples are illustrative inputs, not material standards. Editing an input selects Custom.

Saturated soil · laminar Darcy flow · K at test conditions. No temperature correction.

Choose the laboratory method matching your recorded measurements.
Distance between the two head-measurement locations along the sample.
cm
Area normal to flow. For a circular sample use π × internal diameter² / 4, in cm².
cm²
Duration over which the volume was collected or the standpipe fell.
s
Total head difference across the sample. In falling head, the initial level above the fixed downstream water level.
cm

Total head difference across the sample. In falling head, the initial level above the fixed downstream water level.

Water collected during the entered elapsed time, after steady flow is established. 1 mL = 1 cm³.
mL
Use the internal bore diameter, not the outside tube diameter.
mm
Final level above the same fixed downstream water level. Must be positive and below the initial head.
cm

Final level above the same fixed downstream water level. Must be positive and below the initial head.

Visual
Permeability test diagramSchematic of constant head and flow through a saturated sample.
Output
Hydraulic conductivity K
—

Length per time · soil and fluid together

—
K in centimetres per second

Saturated, laminar flow. Heads share a fixed downstream datum. K is at test conditions; no temperature correction.

Equation and substitutions

K = VL/(Aht). Use consistent length units and elapsed time.

Hydraulic conductivity and intrinsic permeability

"Permeability" is used for two related quantities, and picking the wrong one is the most common source of confusion.

Quantity Symbol Units Depends on
Hydraulic conductivity KK m/s, cm/s, m/day The porous medium and the fluid (density, viscosity)
Intrinsic permeability kk m², darcy (D), millidarcy (mD), µm² The medium only: pore size, shape and connectivity

Soil laboratory tests determine KK from measurements made with a particular fluid (usually water) at a particular temperature. Intrinsic permeability is the property to use when the fluid changes, as in comparing water with oil or brine, or when you want to describe the medium itself. The two are linked by

K=k ρ gμ,k=K μρ gK = \frac{k\,\rho\,g}{\mu}, \qquad k = \frac{K\,\mu}{\rho\,g}

where ρ\rho is fluid density, g=9.80665 m/s2g = 9.80665\ \mathrm{m/s^2} and μ\mu is dynamic viscosity.

Which permeability equation fits your data

The right permeability equation depends on what you measured and what you want to know.

You have You want Use Calculator setting
Volume collected over time under a steady head difference KK Constant-head equation Simple, Constant-head test
A timed drop in standpipe water level KK Falling-head equation Simple, Falling-head test
KK in one unit, or kk in another, plus fluid properties The other quantity or unit K=kρg/μK = k\rho g/\mu Advanced, Convert K, k and units
Porosity and a representative grain diameter, no test A model estimate of kk Kozeny–Carman Advanced, Estimate k from porosity

Simple mode is the default and covers the two laboratory tests. Advanced mode handles conversion and the porosity-based estimate.

Constant head permeability test calculation

In a constant-head test, a fixed head difference is maintained across the sample, flow reaches steady state, and the water passing through is collected over a measured time. The calculation is

K=V LA Δh tK = \frac{V\,L}{A\,\Delta h\,t}
Symbol Meaning Calculator unit
VV Volume collected during tt, after steady flow is established mL
LL Sample length, the distance between the head-measurement locations cm
AA Cross-sectional area normal to flow cm²
Δh\Delta h Maintained total head difference across the sample cm
tt Elapsed collection time s

Because 1 mL = 1 cm³, these units give KK in cm/s directly. Divide by 100 for m/s.

The equation is Darcy's law rearranged. The discharge per unit area is the Darcy flux q=V/(A t)q = V/(A\,t), the hydraulic gradient is i=Δh/Li = \Delta h/L, and K=q/iK = q/i. If you want a quick sanity check on a measurement, compute qq and ii separately and confirm that the ratio is plausible for the material.

Constant-head tests are generally better suited to coarser, more permeable soils such as sands and gravels, where enough water passes through in a reasonable time to measure accurately. For fine-grained soils the flow can be too small to collect reliably, and the falling-head method is usually preferred.

Falling head permeability test calculation

In a falling-head test, water flows through the sample from a standpipe, and you record how long the water level takes to drop from an initial head to a final head. The downstream water level stays fixed.

Falling head permeability test formula

K=a LA t ln⁡ ⁣(h1h2),a=πd24K = \frac{a\,L}{A\,t}\,\ln\!\left(\frac{h_1}{h_2}\right), \qquad a = \frac{\pi d^2}{4}
Symbol Meaning Calculator unit
aa Standpipe cross-sectional area from bore diameter
dd Standpipe internal bore diameter mm
LL Sample length cm
AA Sample cross-sectional area cm²
tt Time for the head to fall from h1h_1 to h2h_2 s
h1h_1 Initial head above the fixed downstream level cm
h2h_2 Final head above the same downstream level cm

The logarithm is natural (ln⁡\ln, base ee), not base 10. Using log⁡10\log_{10} by mistake changes the answer by a factor of about 2.303, which is a common error when working from a textbook form written with 2.303log⁡102.303\log_{10}.

Units need care. The bore is entered in millimetres, so convert it to centimetres (divide by 10) when working the centimetre form of the equation by hand, or convert every dimension to metres for a result in m/s. The ratio h1/h2h_1/h_2 is dimensionless, so the head unit cancels as long as both readings use the same unit. They must also be measured from the same fixed downstream water level. The calculator requires 0<h2<h10 < h_2 < h_1.

The equation comes from continuity. Flow out of the standpipe equals flow through the sample:

−a dhdt=K hL A-a\,\frac{dh}{dt} = K\,\frac{h}{L}\,A

Integrating from h1h_1 to h2h_2 gives the formula above. The same derivation implies that the head decays exponentially, h(t)=h1 e−KAt/(aL)h(t) = h_1\,e^{-K A t/(a L)}. The half-head time, the time for the head to fall to half its starting value, is therefore ln⁡2⋅aL/(KA)\ln 2 \cdot aL/(KA). The calculator's falling-head diagram plots this decay curve from your two readings. The half-head time it shows is a model prediction, not an additional measurement.

You may encounter this falling head test calculation under names such as the standpipe test or variable-head test. The equation here applies to a fixed downstream water level.

Readings that are close together. When h1h_1 and h2h_2 are nearly equal, the logarithm is small and any reading error becomes a large fraction of it. For accepted readings, the calculator subtracts the heads in decimal arithmetic before evaluating ln⁡(1+(h1−h2)/h2)\ln(1 + (h_1 - h_2)/h_2) with a numerically stable routine. If the readings round to the same number at the calculator's working precision, the tool rejects them as equal. A larger measurable head drop reduces the relative effect of reading error.

Entering measurements correctly

Define each input the way the test defines it. A misread measurement can still fall within the calculator's accepted range.

  • Sample length LL is the distance between the head-measurement locations, not necessarily the overall length of the specimen holder.
  • Area AA is the cross section normal to flow. For a circular sample, A=πD2/4A = \pi D^2/4 using the internal diameter DD.
  • Time tt is the collection interval for a constant-head test, or the time between the two head readings for a falling-head test.
  • Head in a constant-head test is the maintained total head difference Δh\Delta h. In a falling-head test, h1h_1 and h2h_2 are heads above the fixed downstream level.
  • Standpipe diameter is the internal bore, not the outer diameter.
Field Unit Default Typed range
Sample length cm 10 0.01–100
Cross-sectional area cm² 50 0.01–10,000
Elapsed time s 60 0.01–604,800
Head difference or initial head cm 20 0.01–1,000
Collected volume (constant head) mL 60 0.001–1,000,000
Standpipe internal diameter (falling head) mm 4 0.01–100
Final head (falling head) cm 10 0.001–999
Fluid density (conversion) kg/m³ 1,000 1–20,000
Dynamic viscosity (conversion) mPa·s 1 0.001–1,000,000
Porosity (estimate) % 40 1–70
Representative grain diameter (estimate) mm 0.5 0.001–10

Fields accept decimals and scientific notation (for example 1e-4). The sliders start with narrower ranges than the typed limits, so you can type a value outside the slider span and it will still be accepted if it is within the typed range. If an entry is invalid, the results clear to an em dash, the problem input is identified, and Copy and Export are disabled until it is fixed.

Worked examples

The calculator's built-in presets use these values, so you can load one and compare it with the hand calculation.

Constant head. With L=10L = 10 cm, A=50A = 50 cm², t=60t = 60 s, Δh=20\Delta h = 20 cm and V=60V = 60 mL:

K=60×1050×20×60=0.01 cm/s=1.000×10−4 m/sK = \frac{60 \times 10}{50 \times 20 \times 60} = 0.01\ \mathrm{cm/s} = 1.000\times10^{-4}\ \mathrm{m/s}

As a check, q=60/(50×60)=0.02q = 60/(50 \times 60) = 0.02 cm/s and i=20/10=2i = 20/10 = 2, so K=q/i=0.01K = q/i = 0.01 cm/s.

Falling head. With L=10L = 10 cm, A=50A = 50 cm², t=60t = 60 s, h1=20h_1 = 20 cm, h2=10h_2 = 10 cm and a 4 mm bore (0.4 cm), the standpipe area is a=π(0.4)2/4≈0.1257a = \pi(0.4)^2/4 \approx 0.1257 cm². Then:

K=a×1050×60 ln⁡(2)≈2.903×10−4 cm/s=2.903×10−6 m/sK = \frac{a \times 10}{50 \times 60}\,\ln(2) \approx 2.903\times10^{-4}\ \mathrm{cm/s} = 2.903\times10^{-6}\ \mathrm{m/s}

Use the unrounded area a=π(0.4)2/4a = \pi(0.4)^2/4 for the calculation. Here the head halves in exactly 60 s, so the modelled half-head time equals the elapsed time.

Conversion. For K=1×10−4K = 1\times10^{-4} m/s, ρ=1,000\rho = 1{,}000 kg/m³ and μ=1\mu = 1 mPa·s (0.001 Pa·s):

k=Kμρg=10−4×10−31000×9.80665≈1.020×10−11 m2≈10.33 Dk = \frac{K\mu}{\rho g} = \frac{10^{-4} \times 10^{-3}}{1000 \times 9.80665} \approx 1.020\times10^{-11}\ \mathrm{m^2} \approx 10.33\ \mathrm{D}

Porosity estimate. For n=0.40n = 0.40 and d=0.5d = 0.5 mm:

k=(5×10−4)2(0.4)3180 (0.6)2≈2.469×10−10 m2≈250.2 Dk = \frac{(5\times10^{-4})^2 (0.4)^3}{180\,(0.6)^2} \approx 2.469\times10^{-10}\ \mathrm{m^2} \approx 250.2\ \mathrm{D}

Results display to four significant digits, with trailing zeroes dropped in ordinary decimal display. Nonzero values below 0.001 or at least 100,000 appear in scientific notation, which is why KK for the constant-head example shows as 1.000e-4 in m/s but 0.01 in cm/s.

Permeability conversion calculator for K, k and units

Advanced mode has two kinds of conversion, and they behave differently.

Converting units within the same quantity (for example, m/day to m/s, or mD to m²) uses fixed factors and does not depend on the fluid inputs:

Quantity Conversion used
Time 1 day = 86,400 s
Intrinsic permeability 1 D = 9.869233×10−139.869233\times10^{-13} m²
Intrinsic permeability 1 mD = 0.001 D
Intrinsic permeability 1 µm² = 10−1210^{-12} m²
Viscosity 1 mPa·s = 1 cP = 0.001 Pa·s

Converting between KK and kk applies K=kρg/μK = k\rho g/\mu and does depend on density and viscosity. The values must match the fluid and conditions under which the conductivity applies. The defaults (1,000 kg/m³, 1 mPa·s) are illustrative and close to fresh water at around 20 °C, not a substitute for the real fluid properties of your test.

Changing the source unit reinterprets the number already in the field, keeping its digits as entered. If you typed 10 while the unit was mD and switch to D, the calculator now reads 10 D. Re-enter or check the value after changing the unit.

As a rough scale for water under these defaults, 1 D corresponds to K≈9.7×10−6K \approx 9.7\times10^{-6} m/s. The result cards show KK in m/s and cm/s and kk in m² and D.

Temperature and fluid effects

Because KK scales with ρ/μ\rho/\mu, a conductivity measured with cold water will be lower than the same soil tested with warm water. The Simple-mode tests apply no automatic temperature correction, so the reported KK is the conductivity at your test conditions. If you need to report or compare values at a reference temperature, a common approach is to convert to intrinsic permeability with the viscosity and density at the test temperature, then back to KK with the viscosity and density at the reference temperature. This is a fluid-property adjustment only. It does not correct for dissolved air, chemistry or sample changes.

Permeability calculation from porosity

When no test data are available, the Kozeny–Carman relation gives a model estimate of intrinsic permeability from porosity and a representative grain size:

k=d2 n3180 (1−n)2k = \frac{d^2\,n^3}{180\,(1 - n)^2}

Here dd is the representative spherical-grain diameter in metres (entered in mm) and nn is porosity as a fraction (entered as a percentage). Porosity is pore volume divided by total bulk volume. The estimate needs both inputs and uses no fluid properties, because it returns kk, a property of the medium.

The relation shows how strongly permeability responds to its inputs:

  • kk scales with d2d^2, so halving the grain diameter cuts kk to one quarter.
  • kk scales with n3/(1−n)2n^3/(1-n)^2, which rises steeply with porosity. Dropping porosity from 40% to 30% at the same grain size lowers kk by a factor of about 3.2.

The porosity diagram plots estimated kk on a logarithmic axis against porosity at your entered grain diameter and marks the current estimate, which makes this sensitivity easy to see.

Limitations. The coefficient of 180 belongs to an idealized packing of uniform spherical grains. Real soils have mixed grain sizes, angular particles, layering and pore networks that this model does not capture, and the choice of "representative" diameter materially changes the answer. The estimate has limited applicability to clays, where particle surface effects and structure dominate, and to fractured rock, where flow follows fractures rather than the pore matrix. Treat the output as an order-of-magnitude screening value and prefer a measured result when you have one. The calculator labels this result as an estimate for that reason.

To get a conductivity from the estimate, take the kk it reports (in m²), switch to Advanced conversion, enter it with the m² unit, and supply the fluid density and viscosity. For the 40% porosity, 0.5 mm example with water, this gives K≈2.4×10−3K \approx 2.4\times10^{-3} m/s.

Assumptions and limitations of the laboratory tests

Both laboratory calculations assume a saturated sample and incompressible, single-phase, laminar (Darcy) flow. Several practical conditions follow from that:

  • Saturation. Trapped air reduces the effective flow area and lowers the apparent KK. Deaired water and adequate saturation procedures matter.
  • Flow regime. Darcy's law is linear in gradient. At very high gradients or in coarse gravels, flow can become non-laminar and the computed KK will no longer be a constant.
  • Sample integrity. Leakage along the specimen wall, particle migration or consolidation during the test violate the model. Compressible soils may change length and porosity as heads change.
  • Falling-head specifics. The standpipe must have a uniform bore, and the downstream level must stay fixed. Both heads must be measured from that same level.
  • Result meaning. The output is hydraulic conductivity at the test conditions, with no automatic temperature correction.

The calculator itself uses JavaScript floating-point arithmetic. Reported digits reflect the display convention, not the precision of your measurements. A result shown to four significant digits is rarely known that precisely in practice.

Interactive diagram, copy and export

The diagram beside the inputs updates with the selected task. For a constant-head test it shows the downstream datum, collected flow rate, head gradient and Darcy flux. For a falling-head test it shows both heads against the fixed datum and the modelled head-decay curve. The conversion view illustrates how KK and kk relate through the fluid, and the porosity view shows the kk versus porosity curve. Laboratory geometry is schematic, not to scale. Controls support zoom, pan and viewport reset.

The expandable Equation and substitutions panel shows the formula with your numbers inserted. Copy collects the active inputs, units, results, assumptions and any advisories. Export opens your browser's print dialog, where you can choose Save as PDF. Reset restores the Simple constant-head task and all default values. Loading a preset selects its mode and task, and editing any input returns the preset selector to Custom.

Relative permeability and magnetic permeability

This tool handles single-phase flow of one fluid through a saturated medium. It does not calculate relative permeability for multiphase flow (such as oil, water and gas saturations), and it does not calculate magnetic permeability. Those require different inputs and relationships, so a relative permeability calculator is a separate tool.

Frequently asked questions

Which test should I choose? Use the constant-head test when you maintained a steady head difference and collected discharge, typically with more permeable soils. Use the falling-head test when you recorded how long the standpipe level took to fall between two readings, typically with lower-permeability soils.

Why is my falling-head result rejected? The calculator requires 0<h2<h10 < h_2 < h_1, with both heads measured above the same fixed downstream level. Equal heads give a zero logarithm, a rising head gives a negative logarithm, and a zero final head makes the ratio undefined.

Why does the result show in both m/s and cm/s? Laboratory reports commonly use cm/s, while SI work uses m/s. They differ by a factor of 100.

Is hydraulic conductivity the same as permeability? Not exactly. Hydraulic conductivity KK includes the effect of the fluid, while intrinsic permeability kk describes the medium alone. Use the conversion task with the correct density and viscosity to move between them.

Can I use the porosity estimate for design values? It is a model estimate for idealized grain packings. Use measured data where possible, and be cautious with clays and fractured rock.

Calculation Methodology Documented

Read the formula definitions, supported input ranges, and limitations before using this estimate.

Review Methodology
Debjeet Bhowmick
Author Debjeet Bhowmick AWS Certified Solutions Architect • Cloud & DevOps Consultant

AWS Certified Solutions Architect Professional and Senior Cloud & DevOps Consultant with over 14 years of hands-on expertise architecting resilient cloud infrastructure across AWS, GCP, and Azure. Specializes in infrastructure as code, continuous delivery automation, and telemetry across Terraform, Ansible, Docker, Kubernetes, ELK, Python, and SQL. Creator of OrangeCalc, delivering client-side high-precision computational tools.