Home Calculators Categories Category: Science & Engineering

Arrhenius equation calculator

Use this Arrhenius equation calculator to predict a rate constant at a target temperature when you know the activation energy. Choose From A if you have the pre-exponential factor, or Two temperatures if you know the rate constant at a reference temperature.

Input
Load sample inputs for either method. Editing any input switches to Custom inputs.
Set the temperature for the predicted rate. The header changes temperature units.
K

Temperature at which you want to predict k.

Use kJ/mol. Divide a value in J/mol by 1,000 before entering it.
kJ/mol

Enter the molar activation energy, including its sign.

Use positive A. A first-order reaction often uses s⁻¹.

Enter A in the units you want for the result.

Assumes constant activation energy and pre-exponential factor over this temperature range.

Visual
Predicted rate constant versus temperature
Output
Predicted rate constant
18.1501

Same units as the pre-exponential factor A.

Which calculation method should you use?

What you know besides activation energy and target temperature Mode Results
Pre-exponential factor AA From A Predicted rate constant
Rate constant k1k_1 at reference temperature T1T_1 Two temperatures Predicted rate constant and Change from reference rate
  1. Select the mode that matches your data.
  2. Choose K or °C in the workspace header. The choice applies to both temperatures, and switching units converts valid entries without changing the prediction.
  3. Enter the target temperature and the activation energy in kJ/mol.
  4. Enter either AA, or both the reference temperature and k1k_1.
  5. Read the result in the same rate-constant units as AA or k1k_1.

Each method uses only its active inputs. Both require a known activation energy. The calculator does not estimate activation energy, fit a rate law or calculate a reaction rate from concentrations.

Arrhenius equations used by the calculator

From a pre-exponential factor

k=Aexp⁡(−EaRT)k=A\exp\left(-\frac{E_a}{RT}\right)
  • kk is the predicted rate constant.
  • AA is the pre-exponential factor.
  • EaE_a is the molar activation energy in J/mol.
  • R=8.31446261815324 J/(mol⋅K)R=8.31446261815324\,\mathrm{J/(mol\cdot K)} is the gas constant.
  • TT is the target temperature in kelvin.

From a rate constant at another temperature

k2=k1exp⁡[EaR(1T1−1T2)]k_2=k_1\exp\left[\frac{E_a}{R}\left(\frac{1}{T_1}-\frac{1}{T_2}\right)\right]

Here, k1k_1 is the known rate constant at the reference temperature T1T_1, and k2k_2 is the prediction at the target temperature T2T_2. Both temperatures must be in kelvin. You do not need AA because it cancels.

Change from reference rate is the ratio k2/k1k_2/k_1. For example, 2× means the predicted rate constant is twice the reference value, while 0.5× means it is half. It is a multiplier, not a percentage increase.

Arrhenius equation units

Quantity Calculator input or output Unit used in a manual calculation
Temperature K or °C K
Activation energy kJ/mol J/mol with the value of RR above
Pre-exponential factor AA Positive number Same units as kk
Reference rate constant k1k_1 Positive number Same units required for k2k_2
Ea/(RT)E_a/(RT) and exp⁡[−Ea/(RT)]\exp[-E_a/(RT)] Used internally Dimensionless
k2/k1k_2/k_1 Ratio with × suffix Dimensionless

To convert temperature and activation energy, use:

TK=T∘C+273.15T_{\mathrm K}=T_{\mathrm{^\circ C}}+273.15
Ea (J/mol)=1000×Ea (kJ/mol)E_a\,(\mathrm{J/mol})=1000\times E_a\,(\mathrm{kJ/mol})

The calculator makes these conversions for you. Enter 75 for an activation energy of 75 kJ/mol, not 75,000.

Rate-constant units depend on the rate law. For a rate expressed in mol L−1 s−1\mathrm{mol\,L^{-1}\,s^{-1}}, common cases are:

Overall reaction order Units of the rate constant
Zero mol L−1 s−1\mathrm{mol\,L^{-1}\,s^{-1}}
First s−1\mathrm{s^{-1}}
Second L mol−1 s−1\mathrm{L\,mol^{-1}\,s^{-1}}

The calculator displays a numerical result and identifies which input supplies its units. It does not determine reaction order or convert rate-constant units. If AA is in min−1\mathrm{min^{-1}}, for instance, kk is also in min−1\mathrm{min^{-1}}.

Exponential factor vs. pre-exponential factor

The two factors are different parts of the Arrhenius equation:

k=A⏟pre-exponential factor×exp⁡(−EaRT)⏟exponential factork=\underbrace{A}_{\text{pre-exponential factor}}\times\underbrace{\exp\left(-\frac{E_a}{RT}\right)}_{\text{exponential factor}}

The exponential factor is dimensionless and contains the explicit dependence on activation energy and temperature. The pre-exponential factor, AA, carries the units of the rate constant. In simple collision-based interpretations, AA relates to collision frequency and orientation, while the exponential term relates to the energy requirement. For a general experimental rate constant, both are best treated as parts of a model fitted to data.

For positive EaE_a, the exponential factor lies between 0 and 1 mathematically. It equals 1 when Ea=0E_a=0 and exceeds 1 when EaE_a is negative, so it cannot always be read as a probability or a fraction of molecules.

Arrhenius equation examples

Example 1: Calculate k from A

Suppose a first-order reaction has these illustrative parameters:

  • A=1.0×1013 s−1A=1.0\times10^{13}\,\mathrm{s^{-1}}
  • Ea=75 kJ/mol=75,000 J/molE_a=75\,\mathrm{kJ/mol}=75{,}000\,\mathrm{J/mol}
  • T=25 ∘C=298.15 KT=25\,^\circ\mathrm C=298.15\,\mathrm K

First, calculate the exponent:

−EaRT=−75,000(8.31446261815324)(298.15)≈−30.254659-\frac{E_a}{RT}=-\frac{75{,}000}{(8.31446261815324)(298.15)}\approx-30.254659

The exponential factor is:

e−30.254659≈7.25385×10−14e^{-30.254659}\approx7.25385\times10^{-14}

Multiply it by AA:

k≈(1.0×1013)(7.25385×10−14)=0.725385 s−1k\approx(1.0\times10^{13})(7.25385\times10^{-14})=0.725385\,\mathrm{s^{-1}}

To reproduce this result, select From A, choose °C, and enter a target temperature of 25, activation energy of 75 and AA of 1e13.

Example 2: Predict k at a second temperature

A rate constant is 0.0025 s−10.0025\,\mathrm{s^{-1}} at 298.15 K. Predict it at 308.15 K, assuming Ea=50 kJ/molE_a=50\,\mathrm{kJ/mol}.

ln⁡(k2k1)=50,0008.31446261815324(1298.15−1308.15)≈0.654544\ln\left(\frac{k_2}{k_1}\right)=\frac{50{,}000}{8.31446261815324}\left(\frac{1}{298.15}-\frac{1}{308.15}\right)\approx0.654544
k2k1=e0.654544≈1.92426\frac{k_2}{k_1}=e^{0.654544}\approx1.92426
k2≈(0.0025)(1.924265)=0.00481066 s−1k_2\approx(0.0025)(1.924265)=0.00481066\,\mathrm{s^{-1}}

The model predicts that this 10 K increase multiplies the rate constant by about 1.92. This is not a universal rule. From 300 K to 310 K, the multiplier is about 1.91 for Ea=50E_a=50 kJ/mol and 3.64 for Ea=100E_a=100 kJ/mol.

Calculator presets

The Examples selector provides two quick checks. Both use Ea=10E_a=10 kJ/mol.

Preset Inputs Displayed results
From a known factor T=300T=300 K; A=1000A=1000 18.1501
From a known rate T1=250T_1=250 K; T2=300T_2=300 K; k1=0.1k_1=0.1 0.222959 and 2.22959×

Each predicted rate constant takes the units associated with AA or k1k_1. Editing an input changes the selector to Custom inputs. Reset restores the From a known factor example.

Arrhenius equation in log form

Taking the natural logarithm of the Arrhenius equation gives:

ln⁡k=ln⁡A−EaRT\ln k=\ln A-\frac{E_a}{RT}

The base-10 form is:

log⁡10k=log⁡10A−EaRTln⁡10\log_{10}k=\log_{10}A-\frac{E_a}{RT\ln 10}

In these expressions, kk and AA represent numerical values measured in the same units. Formally, each is divided by that common unit before taking its logarithm. In Example 1, ln⁡k≈−0.321053\ln k\approx-0.321053 and log⁡10k≈−0.139432\log_{10}k\approx-0.139432. A negative logarithm means that the numerical value of kk is between 0 and 1, not that kk is negative.

How to interpret an Arrhenius plot

A conventional linear Arrhenius plot puts ln⁡k\ln k on the vertical axis and reciprocal absolute temperature, 1/T1/T, on the horizontal axis:

ln⁡k=(−EaR)1T+ln⁡A\ln k=\left(-\frac{E_a}{R}\right)\frac{1}{T}+\ln A

When AA and EaE_a are constant:

  • The slope is −Ea/R-E_a/R.
  • The intercept at 1/T=01/T=0 is ln⁡A\ln A. It is usually an extrapolation far beyond measured data.
  • If log⁡10k\log_{10}k is plotted instead, the slope is −Ea/(Rln⁡10)-E_a/(R\ln10) and the intercept is log⁡10A\log_{10}A.

The calculator's chart has different axes: it shows log⁡10k\log_{10}k against temperature in K or °C. It is generally curved when activation energy is nonzero and horizontal when activation energy is zero. A one-unit increase on its vertical axis represents a tenfold increase in the rate constant. The chart marks the target and, in Two temperatures mode, the reference point.

Derivation of the log and two-temperature equations

The Arrhenius equation is a model of how rate constants depend on temperature. The steps below start with that model and derive its working forms; they do not derive the model from molecular theory.

Start with:

k=Ae−Ea/(RT)k=Ae^{-E_a/(RT)}

Take the natural logarithm of both sides, using consistent units for kk and AA. The logarithm of a product is the sum of the logarithms, and ln⁡(ex)=x\ln(e^x)=x. Therefore:

ln⁡k=ln⁡A−EaRT\ln k=\ln A-\frac{E_a}{RT}

For the same reaction and rate law, assume that AA and EaE_a stay constant between two temperatures. Then:

ln⁡k1=ln⁡A−EaRT1\ln k_1=\ln A-\frac{E_a}{RT_1}
ln⁡k2=ln⁡A−EaRT2\ln k_2=\ln A-\frac{E_a}{RT_2}

Subtract the first equation from the second. The ln⁡A\ln A terms cancel:

ln⁡k2−ln⁡k1=−EaRT2+EaRT1\ln k_2-\ln k_1=-\frac{E_a}{RT_2}+\frac{E_a}{RT_1}

Combine the logarithms and factor out Ea/RE_a/R:

ln⁡(k2k1)=EaR(1T1−1T2)\ln\left(\frac{k_2}{k_1}\right)=\frac{E_a}{R}\left(\frac{1}{T_1}-\frac{1}{T_2}\right)

Finally, exponentiate both sides and multiply by k1k_1:

k2=k1exp⁡[EaR(1T1−1T2)]k_2=k_1\exp\left[\frac{E_a}{R}\left(\frac{1}{T_1}-\frac{1}{T_2}\right)\right]

How to interpret the predicted rate constant

Condition When temperature increases When temperature decreases
Ea>0E_a>0 kk increases kk decreases
Ea<0E_a<0 kk decreases kk increases
Ea=0E_a=0 kk stays constant kk stays constant

These trends assume constant AA and EaE_a. With zero activation energy, From A gives k=Ak=A. In Two temperatures mode, either zero activation energy or equal temperatures gives k2=k1k_2=k_1 and a ratio of 1.

A negative value can describe the apparent activation energy of some kinetic processes. When you enter a valid negative value, the calculator shows the Negative activation energy advisory. Check the sign and stay within the temperature range supported by your data.

A rate constant is not the same as a reaction rate. A reaction rate also depends on the rate law and the relevant concentrations or other state variables. A twofold change in kk gives a twofold change in rate only if the rest of the rate expression is unchanged.

Common mistakes and model limits

  • Using Celsius directly in the equation: In Example 2, substituting 25 and 35 for the kelvin temperatures gives a ratio of about 7.04×10297.04\times10^{29} instead of 1.92. The calculator's °C option performs the conversion correctly.
  • Mixing J and kJ: With RR in J/(mol·K), EaE_a must be in J/mol in a manual calculation. Using 75 instead of 75,000 in Example 1 gives about 9.70×1012 s−19.70\times10^{12}\,\mathrm{s^{-1}} instead of 0.725385 s−10.725385\,\mathrm{s^{-1}}.
  • Reversing the two temperatures: Keep k1k_1 paired with T1T_1. The target temperature is T2T_2.
  • Rounding too early: Keep extra digits in the exponent and round the final answer.
  • Treating displayed digits as certainty: The calculator provides no uncertainty estimate. Uncertainty in AA, k1k_1 or EaE_a can affect the prediction. In Example 1, changing EaE_a from 75 to 76 kJ/mol lowers kk by about 33% when AA and temperature stay fixed.
  • Extrapolating too far: The prediction assumes the same reaction and rate law, with constant AA and EaE_a over the applicable interval. A change in mechanism or controlling process, such as a shift to transport limitation, can invalidate that assumption.

Use parameters from compatible conditions and check the temperature range of the underlying data. An input accepted by the calculator is not necessarily physically valid for your reaction.

Arrhenius equation practice problems

Try each problem before checking the answers. Use R=8.31446261815324 J/(mol⋅K)R=8.31446261815324\,\mathrm{J/(mol\cdot K)}.

  1. Known pre-exponential factor: Find kk at 350 K when A=5.0×1011 s−1A=5.0\times10^{11}\,\mathrm{s^{-1}} and Ea=60E_a=60 kJ/mol.
  2. Cooling: A rate constant is 0.040 L mol−1 s−10.040\,\mathrm{L\,mol^{-1}\,s^{-1}} at 50 °C. Find it at 25 °C when Ea=65E_a=65 kJ/mol.
  3. Negative activation energy: A rate constant is 0.015 s−10.015\,\mathrm{s^{-1}} at 300 K. Find it at 350 K when Ea=−8E_a=-8 kJ/mol.
  4. Celsius input: Find kk at 100 °C when A=2.0×108 min−1A=2.0\times10^8\,\mathrm{min^{-1}} and Ea=45E_a=45 kJ/mol.

Answers

1. Use the From A equation:

k=(5.0×1011)exp⁡[−60,000R(350)]≈555.437 s−1k=(5.0\times10^{11})\exp\left[-\frac{60{,}000}{R(350)}\right]\approx555.437\,\mathrm{s^{-1}}

The exponent is about −20.6181-20.6181.

2. Convert the temperatures to T1=323.15T_1=323.15 K and T2=298.15T_2=298.15 K:

k2=0.040exp⁡[65,000R(1323.15−1298.15)]≈0.00526118 L mol−1 s−1k_2=0.040\exp\left[\frac{65{,}000}{R}\left(\frac{1}{323.15}-\frac{1}{298.15}\right)\right]\approx0.00526118\,\mathrm{L\,mol^{-1}\,s^{-1}}

The ratio is about 0.131529. Cooling lowers kk because EaE_a is positive.

3. Keep the negative sign on EaE_a:

k2=0.015exp⁡[−8,000R(1300−1350)]≈0.00948650 s−1k_2=0.015\exp\left[\frac{-8{,}000}{R}\left(\frac{1}{300}-\frac{1}{350}\right)\right]\approx0.00948650\,\mathrm{s^{-1}}

The ratio is about 0.632433. Here, warming lowers kk.

4. Convert 100 °C to 373.15 K:

k=(2.0×108)exp⁡[−45,000R(373.15)]≈100.443 min−1k=(2.0\times10^8)\exp\left[-\frac{45{,}000}{R(373.15)}\right]\approx100.443\,\mathrm{min^{-1}}

Input ranges and calculator features

Input Default Accepted values
Target temperature 300 K (26.85 °C) 1 to 10,000 K, or −272.15 to 9,726.85 °C; up to six decimal places
Reference temperature 250 K (−23.15 °C) Same limits and precision as target temperature
Activation energy 10 kJ/mol −500 to 500 kJ/mol
Pre-exponential factor AA 1000 Positive values from 1e-100 to 1e100
Reference rate constant k1k_1 0.1 Positive values from 1e-100 to 1e100

All range endpoints are included. Numeric entry supports scientific notation, such as 2.5e-3. Temperature sliders move in 1-degree steps, and the activation-energy slider moves in 0.1 kJ/mol steps. The AA and k1k_1 sliders move in increments of 0.1 on a base-10 logarithmic scale. Their initial span of 1e-8 to 1e8 can expand to accommodate direct entries.

If an active input is missing or out of range, a validation message appears, the affected results show a dash and the chart clears. Inactive inputs are ignored.

The calculator uses integer microkelvin for temperature conversion and base-10 logarithms for rate and ratio calculations. Results are rounded to six significant digits, with trailing zeros omitted. Very small or large results appear in scientific notation, including values outside the ordinary floating-point range.

Use Copy to capture the active inputs and results, or Export/Print to open your browser's print dialog. Built-in help covers both methods, units, inputs, the chart, and the save and reset controls. When saving a result, add the appropriate rate-constant units and note the source and applicable temperature range of your parameters.

Frequently asked questions

Can I use the Arrhenius equation without A?

Yes. If you know EaE_a and a rate constant at a reference temperature, use Two temperatures. The pre-exponential factor cancels from the calculation.

Can this calculator find activation energy from two rate constants?

No. It predicts a rate constant using a known activation energy. Its Two temperatures mode accepts one reference rate constant and calculates the second.

Can the predicted rate constant be greater than 1?

Yes. A rate constant can be greater than 1, and its numerical value depends on its units. This is different from the exponential factor, which is dimensionless and is below 1 when activation energy is positive.

Calculation Methodology Documented

Read the formula definitions, supported input ranges, and limitations before using this estimate.

Review Methodology
Debjeet Bhowmick
Author Debjeet Bhowmick AWS Certified Solutions Architect • Cloud & DevOps Consultant

AWS Certified Solutions Architect Professional and Senior Cloud & DevOps Consultant with over 14 years of hands-on expertise architecting resilient cloud infrastructure across AWS, GCP, and Azure. Specializes in infrastructure as code, continuous delivery automation, and telemetry across Terraform, Ansible, Docker, Kubernetes, ELK, Python, and SQL. Creator of OrangeCalc, delivering client-side high-precision computational tools.