Which calculation method should you use?
| What you know besides activation energy and target temperature | Mode | Results |
|---|---|---|
| Pre-exponential factor | From A | Predicted rate constant |
| Rate constant at reference temperature | Two temperatures | Predicted rate constant and Change from reference rate |
- Select the mode that matches your data.
- Choose K or °C in the workspace header. The choice applies to both temperatures, and switching units converts valid entries without changing the prediction.
- Enter the target temperature and the activation energy in kJ/mol.
- Enter either , or both the reference temperature and .
- Read the result in the same rate-constant units as or .
Each method uses only its active inputs. Both require a known activation energy. The calculator does not estimate activation energy, fit a rate law or calculate a reaction rate from concentrations.
Arrhenius equations used by the calculator
From a pre-exponential factor
- is the predicted rate constant.
- is the pre-exponential factor.
- is the molar activation energy in J/mol.
- is the gas constant.
- is the target temperature in kelvin.
From a rate constant at another temperature
Here, is the known rate constant at the reference temperature , and is the prediction at the target temperature . Both temperatures must be in kelvin. You do not need because it cancels.
Change from reference rate is the ratio . For example, 2× means the predicted rate constant is twice the reference value, while 0.5× means it is half. It is a multiplier, not a percentage increase.
Arrhenius equation units
| Quantity | Calculator input or output | Unit used in a manual calculation |
|---|---|---|
| Temperature | K or °C | K |
| Activation energy | kJ/mol | J/mol with the value of above |
| Pre-exponential factor | Positive number | Same units as |
| Reference rate constant | Positive number | Same units required for |
| and | Used internally | Dimensionless |
Ratio with × suffix |
Dimensionless |
To convert temperature and activation energy, use:
The calculator makes these conversions for you. Enter 75 for an activation energy of 75 kJ/mol, not 75,000.
Rate-constant units depend on the rate law. For a rate expressed in , common cases are:
| Overall reaction order | Units of the rate constant |
|---|---|
| Zero | |
| First | |
| Second |
The calculator displays a numerical result and identifies which input supplies its units. It does not determine reaction order or convert rate-constant units. If is in , for instance, is also in .
Exponential factor vs. pre-exponential factor
The two factors are different parts of the Arrhenius equation:
The exponential factor is dimensionless and contains the explicit dependence on activation energy and temperature. The pre-exponential factor, , carries the units of the rate constant. In simple collision-based interpretations, relates to collision frequency and orientation, while the exponential term relates to the energy requirement. For a general experimental rate constant, both are best treated as parts of a model fitted to data.
For positive , the exponential factor lies between 0 and 1 mathematically. It equals 1 when and exceeds 1 when is negative, so it cannot always be read as a probability or a fraction of molecules.
Arrhenius equation examples
Example 1: Calculate k from A
Suppose a first-order reaction has these illustrative parameters:
First, calculate the exponent:
The exponential factor is:
Multiply it by :
To reproduce this result, select From A, choose °C, and enter a target temperature of 25, activation energy of 75 and of 1e13.
Example 2: Predict k at a second temperature
A rate constant is at 298.15 K. Predict it at 308.15 K, assuming .
The model predicts that this 10 K increase multiplies the rate constant by about 1.92. This is not a universal rule. From 300 K to 310 K, the multiplier is about 1.91 for kJ/mol and 3.64 for kJ/mol.
Calculator presets
The Examples selector provides two quick checks. Both use kJ/mol.
| Preset | Inputs | Displayed results |
|---|---|---|
| From a known factor | K; | 18.1501 |
| From a known rate | K; K; | 0.222959 and 2.22959× |
Each predicted rate constant takes the units associated with or . Editing an input changes the selector to Custom inputs. Reset restores the From a known factor example.
Arrhenius equation in log form
Taking the natural logarithm of the Arrhenius equation gives:
The base-10 form is:
In these expressions, and represent numerical values measured in the same units. Formally, each is divided by that common unit before taking its logarithm. In Example 1, and . A negative logarithm means that the numerical value of is between 0 and 1, not that is negative.
How to interpret an Arrhenius plot
A conventional linear Arrhenius plot puts on the vertical axis and reciprocal absolute temperature, , on the horizontal axis:
When and are constant:
- The slope is .
- The intercept at is . It is usually an extrapolation far beyond measured data.
- If is plotted instead, the slope is and the intercept is .
The calculator's chart has different axes: it shows against temperature in K or °C. It is generally curved when activation energy is nonzero and horizontal when activation energy is zero. A one-unit increase on its vertical axis represents a tenfold increase in the rate constant. The chart marks the target and, in Two temperatures mode, the reference point.
Derivation of the log and two-temperature equations
The Arrhenius equation is a model of how rate constants depend on temperature. The steps below start with that model and derive its working forms; they do not derive the model from molecular theory.
Start with:
Take the natural logarithm of both sides, using consistent units for and . The logarithm of a product is the sum of the logarithms, and . Therefore:
For the same reaction and rate law, assume that and stay constant between two temperatures. Then:
Subtract the first equation from the second. The terms cancel:
Combine the logarithms and factor out :
Finally, exponentiate both sides and multiply by :
How to interpret the predicted rate constant
| Condition | When temperature increases | When temperature decreases |
|---|---|---|
| increases | decreases | |
| decreases | increases | |
| stays constant | stays constant |
These trends assume constant and . With zero activation energy, From A gives . In Two temperatures mode, either zero activation energy or equal temperatures gives and a ratio of 1.
A negative value can describe the apparent activation energy of some kinetic processes. When you enter a valid negative value, the calculator shows the Negative activation energy advisory. Check the sign and stay within the temperature range supported by your data.
A rate constant is not the same as a reaction rate. A reaction rate also depends on the rate law and the relevant concentrations or other state variables. A twofold change in gives a twofold change in rate only if the rest of the rate expression is unchanged.
Common mistakes and model limits
- Using Celsius directly in the equation: In Example 2, substituting 25 and 35 for the kelvin temperatures gives a ratio of about instead of 1.92. The calculator's °C option performs the conversion correctly.
- Mixing J and kJ: With in J/(mol·K), must be in J/mol in a manual calculation. Using 75 instead of 75,000 in Example 1 gives about instead of .
- Reversing the two temperatures: Keep paired with . The target temperature is .
- Rounding too early: Keep extra digits in the exponent and round the final answer.
- Treating displayed digits as certainty: The calculator provides no uncertainty estimate. Uncertainty in , or can affect the prediction. In Example 1, changing from 75 to 76 kJ/mol lowers by about 33% when and temperature stay fixed.
- Extrapolating too far: The prediction assumes the same reaction and rate law, with constant and over the applicable interval. A change in mechanism or controlling process, such as a shift to transport limitation, can invalidate that assumption.
Use parameters from compatible conditions and check the temperature range of the underlying data. An input accepted by the calculator is not necessarily physically valid for your reaction.
Arrhenius equation practice problems
Try each problem before checking the answers. Use .
- Known pre-exponential factor: Find at 350 K when and kJ/mol.
- Cooling: A rate constant is at 50 °C. Find it at 25 °C when kJ/mol.
- Negative activation energy: A rate constant is at 300 K. Find it at 350 K when kJ/mol.
- Celsius input: Find at 100 °C when and kJ/mol.
Answers
1. Use the From A equation:
The exponent is about .
2. Convert the temperatures to K and K:
The ratio is about 0.131529. Cooling lowers because is positive.
3. Keep the negative sign on :
The ratio is about 0.632433. Here, warming lowers .
4. Convert 100 °C to 373.15 K:
Input ranges and calculator features
| Input | Default | Accepted values |
|---|---|---|
| Target temperature | 300 K (26.85 °C) | 1 to 10,000 K, or −272.15 to 9,726.85 °C; up to six decimal places |
| Reference temperature | 250 K (−23.15 °C) | Same limits and precision as target temperature |
| Activation energy | 10 kJ/mol | −500 to 500 kJ/mol |
| Pre-exponential factor | 1000 | Positive values from 1e-100 to 1e100 |
| Reference rate constant | 0.1 | Positive values from 1e-100 to 1e100 |
All range endpoints are included. Numeric entry supports scientific notation, such as 2.5e-3. Temperature sliders move in 1-degree steps, and the activation-energy slider moves in 0.1 kJ/mol steps. The and sliders move in increments of 0.1 on a base-10 logarithmic scale. Their initial span of 1e-8 to 1e8 can expand to accommodate direct entries.
If an active input is missing or out of range, a validation message appears, the affected results show a dash and the chart clears. Inactive inputs are ignored.
The calculator uses integer microkelvin for temperature conversion and base-10 logarithms for rate and ratio calculations. Results are rounded to six significant digits, with trailing zeros omitted. Very small or large results appear in scientific notation, including values outside the ordinary floating-point range.
Use Copy to capture the active inputs and results, or Export/Print to open your browser's print dialog. Built-in help covers both methods, units, inputs, the chart, and the save and reset controls. When saving a result, add the appropriate rate-constant units and note the source and applicable temperature range of your parameters.
Frequently asked questions
Can I use the Arrhenius equation without A?
Yes. If you know and a rate constant at a reference temperature, use Two temperatures. The pre-exponential factor cancels from the calculation.
Can this calculator find activation energy from two rate constants?
No. It predicts a rate constant using a known activation energy. Its Two temperatures mode accepts one reference rate constant and calculates the second.
Can the predicted rate constant be greater than 1?
Yes. A rate constant can be greater than 1, and its numerical value depends on its units. This is different from the exponential factor, which is dimensionless and is below 1 when activation energy is positive.
Read the formula definitions, supported input ranges, and limitations before using this estimate.