Boiling point pressure calculator

Water does not always boil at 100 °C. The temperature at which a liquid boils depends on the absolute pressure pushing on it: lower pressure means a lower boiling temperature, and higher pressure means a higher one. Enter an absolute pressure below and the calculator returns the boiling temperature of pure water. In Advanced mode it can also work backward from a water temperature to its saturation pressure, or estimate the boiling temperature of another liquid from reference data you provide.

Input

Pure water · equilibrium boiling · enter absolute pressure, not gauge pressure.

Load a pressure example or the reverse water calculation; changing an input returns to Your values.
All pressures are absolute. Unit changes convert valid target and reference pressures. Torr is approximately mmHg.
Choose result units; valid water and reference temperatures convert to preserve their physical values.
Water: 0.611657 kPa to below 22064 kPa, absolute.
kPa

Water: 0.611657 kPa to below 22064 kPa, absolute.

Visual
Boiling point and absolute pressureTemperature on the horizontal axis, logarithmic absolute pressure on the vertical axis. A dot marks the current state; a hollow dot marks a custom reference.
Output
Water boiling temperature
—

Pure water · IAPWS-IF97 equilibrium curve.

What "boiling point" means when pressure changes

A liquid boils when its saturation vapor pressure equals the absolute pressure of its surroundings. Vapor pressure is the pressure of vapor in equilibrium with the liquid at a given temperature, and it rises steeply as the liquid gets hotter. At the temperature where it reaches the external pressure, vapor can form throughout the liquid, and that temperature is the boiling point (also called the saturation temperature).

So "calculating boiling point from vapor pressure" and "calculating boiling point from pressure" are the same problem. You look for the temperature at which the liquid's vapor pressure matches the pressure you care about.

This also explains why the familiar 100 °C is a rounded figure for one specific condition. At exactly one standard atmosphere (101.325 kPa), the water model used here gives 99.97 °C, not 100 °C. Water's vapor pressure at exactly 100 °C is 101.418 kPa, slightly above one atmosphere.

How to use the calculator

Simple mode is the default. It always uses pure water and solves for boiling temperature.

  1. Enter the absolute pressure.
  2. Choose a pressure unit (kPa, bar, atm, psi absolute, or Torr).
  3. Choose a temperature unit for the result (°C, °F, or K).

Advanced mode has two branches:

  • Pure water · IAPWS offers two directions. You can solve for boiling temperature from absolute pressure, or for saturation pressure from a water temperature.
  • Other liquid · estimate solves only for an estimated boiling temperature at a target absolute pressure. It needs a reference pressure, the boiling temperature at that reference pressure, and the molar heat of vaporization of the same pure liquid.

The graph plots temperature on the horizontal axis and absolute pressure on a logarithmic vertical axis. A filled dot marks the calculated state. In other-liquid mode a hollow dot marks your reference point. You can zoom, pan, and reset the view without changing any inputs.

Absolute pressure, not gauge pressure

Every pressure in this calculator is absolute, meaning measured relative to a perfect vacuum. This includes psi, which here always means absolute psi. There is no gauge-pressure mode.

A gauge reads the difference from the surrounding air. For a gauge that reads above atmospheric pressure:

pabs=pgauge+patmp_\text{abs} = p_\text{gauge} + p_\text{atm}

A vacuum gauge may report a positive vacuum magnitude or a signed gauge pressure. Convert its reading according to its own sign convention. Establish local atmospheric pressure and your instrument's convention first, then enter the absolute result. Confusing gauge and absolute pressure changes the state being calculated.

Unit conversions used

Pressure unit Equivalent in kPa
1 kPa 1
1 bar 100
1 atm 101.325
1 psi (absolute) 6.894757293168361
1 Torr 101.325/760 ≈ 0.133322

Torr is approximately the same as mmHg, which is not a separate selector. Temperatures convert as TK=TC+273.15T_\text{K} = T_\text{C} + 273.15 and TK=(TF−32)×59+273.15T_\text{K} = (T_\text{F} - 32)\times\tfrac{5}{9} + 273.15. A temperature difference converts by a factor of 9/59/5 between kelvin or Celsius intervals and Fahrenheit intervals, with no offset.

When you change units, valid entries are converted so they keep the same physical value. An invalid entry stays visible as typed, and the calculator does not silently clamp it.

Boiling temperature of water at different pressures

For pure water, the calculator uses the IAPWS-IF97 Region 4 saturation correlation, an internationally standardized formulation for the liquid–vapor boundary of ordinary water. It does not use a simple Antoine fit or a constant-enthalpy shortcut. The values below come from the same model, rounded to two decimals. The 10 kPa, 101.325 kPa, and 1000 kPa rows match the calculator's three pressure-input presets; the remaining rows provide additional reference pressures.

Absolute pressure Water boiling temperature
10 kPa 45.81 °C
50 kPa 81.32 °C
100 kPa (1 bar) 99.61 °C
101.325 kPa (1 atm) 99.97 °C
200 kPa 120.21 °C
500 kPa 151.84 °C
1000 kPa (1 MPa) 179.89 °C

The relationship is nonlinear. Going from 10 kPa to 100 kPa raises the boiling point by about 54 °C, while going from 100 kPa to 1000 kPa raises it by about 80 °C. Both pressure changes are tenfold increases. The graph uses a logarithmic pressure axis, so equal vertical distances correspond to equal pressure ratios, not equal pressure differences.

Going the other way: saturation pressure from temperature

In Advanced mode, choose pure water and solve for saturation pressure. Enter a water temperature and the calculator returns the absolute pressure at which water boils at that temperature. For 100 °C it returns 101.418 kPa absolute. This is useful when you know the temperature of a vessel and want the pressure below which water in it will start to boil.

The range where the water model applies

The water calculation is valid only for liquid–vapor equilibrium between the triple point and the critical point:

Quantity Accepted range
Pressure 0.611657 kPa (inclusive) to 22064 kPa (exclusive)
Temperature 273.16 K (inclusive) to 647.096 K (exclusive), or 0.01 °C to 373.946 °C

The lower limits are rounded representations of the triple point, where solid, liquid, and vapor coexist. Below the triple-point pressure, there is no stable equilibrium liquid–vapor boiling state for pure water; the equilibrium solid–vapor boundary involves sublimation, which this calculator does not model. The upper limit is the critical point, where the liquid–vapor distinction disappears. Inputs at or above the critical limit, or below the lower limits, are rejected rather than extrapolated.

The equations behind the water result

You do not need the algebra to use the calculator, but it helps to know what is being computed. The IAPWS-IF97 Region 4 correlation (equations 29–31 and Table 34 of the standard) uses ten fixed coefficients, n1n_1 through n10n_{10}.

To find the saturation pressure at temperature TT in kelvin:

θ=T+n9T−n10\theta = T + \frac{n_9}{T - n_{10}}
A=θ2+n1θ+n2A = \theta^2 + n_1\theta + n_2
B=n3θ2+n4θ+n5B = n_3\theta^2 + n_4\theta + n_5
C=n6θ2+n7θ+n8C = n_6\theta^2 + n_7\theta + n_8
pkPa=1000[2C−B+B2−4AC]4p_\text{kPa} = 1000\left[\frac{2C}{-B + \sqrt{B^2 - 4AC}}\right]^4

To find the saturation temperature at pressure pp in kPa, the calculator uses the backward form of the same correlation. It starts from β=(p/1000)1/4\beta = (p/1000)^{1/4}, builds EE, FF, and GG from the coefficients, then computes DD and finally TKT_\text{K} with a closed-form expression. Both directions are evaluated directly, with no iteration or table lookup.

Estimating the boiling point of another liquid

Many people searching for how to calculate boiling point at different pressures are not working with water. The "Other liquid · estimate" option handles that case, but with an important difference: it is an approximation based on data you supply, not a property database.

The model

The calculator uses the integrated Clausius–Clapeyron equation with a constant molar heat of vaporization:

ln⁡PPref=−ΔHvapR(1T−1Tref)\ln\frac{P}{P_\text{ref}} = -\frac{\Delta H_\text{vap}}{R}\left(\frac{1}{T} - \frac{1}{T_\text{ref}}\right)

Solving for the boiling temperature TT at target pressure PP:

T=11Tref−RΔHvapln⁡PPrefT = \frac{1}{\dfrac{1}{T_\text{ref}} - \dfrac{R}{\Delta H_\text{vap}}\ln\dfrac{P}{P_\text{ref}}}

Here TrefT_\text{ref} is the known boiling temperature in kelvin at reference pressure PrefP_\text{ref}, ΔHvap\Delta H_\text{vap} is the molar heat of vaporization in J/mol (you enter kJ/mol and the calculator multiplies by 1000), and R=8.31446261815324R = 8.31446261815324 J/(mol·K). The result is also reported as a change from the reference, ΔT=T−Tref\Delta T = T - T_\text{ref}.

What you must provide

  • A reference absolute pressure for your liquid.
  • The boiling temperature of that same liquid at that pressure.
  • The molar heat of vaporization of that same liquid.

The calculator has no built-in liquid list and cannot identify a liquid or look up its properties. The default inputs (101.325 kPa, 100 °C, 40.65 kJ/mol) are a rounded water illustration, not generic values for any other substance. Replace all three with data for your own liquid.

Worked example

Using those default inputs as a test case, estimate the boiling temperature at a target pressure of 50 kPa.

With Tref=373.15T_\text{ref} = 373.15 K and ΔHvap=40 650\Delta H_\text{vap} = 40\,650 J/mol:

ln⁡50101.325≈−0.7063,RΔHvap≈2.045×10−4 K−1\ln\frac{50}{101.325} \approx -0.7063,\qquad \frac{R}{\Delta H_\text{vap}} \approx 2.045\times10^{-4}\ \text{K}^{-1}
1T≈2.6799×10−3+1.445×10−4≈2.8244×10−3 K−1\frac{1}{T} \approx 2.6799\times10^{-3} + 1.445\times10^{-4} \approx 2.8244\times10^{-3}\ \text{K}^{-1}
T≈354.06 K≈80.91 ∘CT \approx 354.06\ \text{K} \approx 80.91\ ^\circ\text{C}

That is a drop of 19.09 K from the reference, rounded to two decimals. For comparison, the IAPWS water model gives 81.32 °C at 50 kPa. The estimate is about 0.4 K lower in this case. Its constant-enthalpy and ideal-vapor assumptions, along with the rounded reference data, distinguish it from the water correlation. This single comparison does not establish an accuracy range for other conditions or liquids.

Assumptions and limits

The estimate assumes:

  • The molar heat of vaporization stays constant over the temperature interval.
  • The vapor behaves as an ideal gas.
  • The liquid's molar volume is negligible compared with the vapor's.
  • The reference data genuinely belong to the same pure liquid.

The calculator accepts a result only if it is finite, above 0 K, and no greater than 10 000 K. That ceiling is a computational acceptance guard, not a statement that the physics holds anywhere near it. The model does not check melting points, critical points, decomposition, or whether a stable liquid–vapor state exists at the result.

Every valid custom-liquid calculation shows an advisory about these assumptions. A second warning appears if the result differs from the reference temperature by more than 20 K. That threshold is a caution flag, not a measured error limit, and a result within 20 K has no certified accuracy either. For critical work, use measured vapor-pressure data or a properly fitted correlation for your specific liquid.

Reading the results

  • Temperature results are shown to 2 decimal places.
  • Pressure results are shown to up to 6 significant digits.
  • Changes from the reference are shown to 2 decimals in your selected temperature unit.

These are display formats, not measurement uncertainty. A result printed as 99.97 °C does not mean real water in a real pot will boil at exactly that temperature. Dissolved solutes, impurities, dissolved air, and thermometer error all matter in practice.

If any active input is empty, malformed, nonfinite, or out of bounds, the field shows an error, the graph clears, and results are replaced with an em dash. Inputs that are not in use for the current calculation are ignored.

Typing values and using sliders

Typed values can fall between the nominal increments, and the calculator does not round them. Plain decimals and scientific notation such as 1e-3 are both accepted. Entering a number beyond a slider's initial range expands the slider. Slider ranges, like the broad numeric editing bounds, are conveniences and are not the same as the physical validity limits described above.

What the calculator does not cover

Several related problems need different tools:

  • Mixtures. It does not compute bubble points or dew points of liquid mixtures.
  • Dissolved solutes. It does not compute boiling-point elevation from salt or sugar.
  • Altitude. It does not convert elevation into pressure. Find the local absolute pressure separately, then enter it.
  • Air or other gases. It does not correct for noncondensable gases mixed with the vapor.
  • Heating time and energy. It does not estimate how long it takes to reach boiling.
  • Equipment design. It is not for vessel design, pressure ratings, or operating-limit decisions.
  • Unspecified liquids. It has no universal vapor-pressure model for an arbitrary liquid.

Tools on the calculator

  • Copy copies the active inputs, selected units, results, and any applicable model cautions.
  • Export opens your browser's print dialog, which you can use to print or save a PDF.
  • Reset restores Simple water mode, 101.325 kPa, °C, and the hidden default values.
  • Split/Stack switches the workspace layout.
  • Presets load four ready-made water cases: 1 atmosphere, 10 kPa absolute, 1 MPa absolute, and the saturation pressure at 100 °C. Loading a preset resets unspecified inputs to their defaults.

There is no CSV download and no dedicated share-link feature. Calculations run locally in your browser using JavaScript floating-point arithmetic, so the same inputs always produce the same output.

Frequently asked questions

Why does water boil at a lower temperature at low pressure?

Boiling begins when the liquid's vapor pressure equals the surrounding pressure. At lower surrounding pressure, water reaches that equality at a lower temperature. For example, at 10 kPa absolute the calculator gives 45.81 °C.

Is the boiling point of water exactly 100 °C?

Not in this model. At 1 atm (101.325 kPa) it returns 99.97 °C. The value 100 °C is a convenient rounding, and water's saturation pressure at exactly 100 °C is 101.418 kPa.

How do I calculate the boiling point of water at a different pressure by hand?

Use the IAPWS-IF97 Region 4 backward equation, with its ten coefficients and pressure in the units required by the formulation. The calculation above summarizes that approach; the full equations and coefficients are in section 8, equations 29–31 and Table 34 of the IAPWS-IF97 release. The Clausius–Clapeyron equation offers a simpler estimate using a reference state and a molar enthalpy such as the rounded water value of 40.65 kJ/mol near 100 °C. Its error is not bounded by this calculator and can become significant away from the reference.

Can I enter gauge pressure?

No. Enter absolute pressure only. Add local atmospheric pressure to a positive gauge reading, and handle vacuum gauges according to their own sign convention.

Can I use the other-liquid mode for ethanol, acetone, or another solvent?

Yes, if you already have reliable reference data for that liquid: a pressure, the boiling temperature at that pressure, and its molar heat of vaporization. The calculator does not supply those values. Treat the result as an estimate, and check that the liquid is stable and not decomposing at the calculated temperature.

Why was my water input rejected?

Water inputs must lie within the supported liquid–vapor range, from 0.611657 kPa up to but not including 22064 kPa, or from 0.01 °C up to but not including 373.946 °C. A lower input is outside the supported stable liquid–vapor equilibrium domain; an input at or above the critical limit has no distinct boiling transition in this model. Malformed entries and values beyond the numeric editing bounds are also rejected.

Does the calculator account for salt or other dissolved substances?

The water model is for pure water; neither model calculates solute effects. Nonvolatile solutes such as salt or sugar raise water's boiling temperature, while mixtures involving volatile components need a different treatment.

Calculation Methodology Documented

Read the formula definitions, supported input ranges, and limitations before using this estimate.

Review Methodology
Debjeet Bhowmick
Author Debjeet Bhowmick AWS Certified Solutions Architect • Cloud & DevOps Consultant

AWS Certified Solutions Architect Professional and Senior Cloud & DevOps Consultant with over 14 years of hands-on expertise architecting resilient cloud infrastructure across AWS, GCP, and Azure. Specializes in infrastructure as code, continuous delivery automation, and telemetry across Terraform, Ansible, Docker, Kubernetes, ELK, Python, and SQL. Creator of OrangeCalc, delivering client-side high-precision computational tools.