Which calculation should you use?
The calculator has two modes. Freezing point is the default.
| If you know... | And want... | Use this mode |
|---|---|---|
| The solute's molality and its van 't Hoff factor | The solution's freezing point and how far it dropped | Freezing point |
| The measured freezing point drop and the masses of solute and solvent | The solute's molar mass | Molar mass |
Both modes use the selected solvent's built-in pure freezing point and cryoscopic constant, which the controls display under Solvent. Temperatures and temperature drops are in °C, and the mass fields are in grams.
The freezing point depression formula
The size of the temperature drop, , is proportional to the effective concentration of dissolved particles:
- is the van 't Hoff factor, a dimensionless number that reflects how many particles each formula unit of solute contributes.
- is the solvent's cryoscopic constant, in °C·kg/mol.
- is the solute molality, in moles of solute per kilogram of solvent.
The product is the effective particle molality. To calculate the freezing point depression, multiply the three quantities. For example, with , water ( °C·kg/mol) and mol/kg:
If you are starting from an amount of solute rather than a molality, divide the moles of solute by the mass of the solvent alone, in kilograms. Do not use the mass of the whole solution.
The freezing point formula
The depression is the amount by which the freezing point falls. To find the freezing temperature of the solution, subtract it from the pure solvent's freezing point:
Continuing the example above, pure water freezes at 0 °C at normal pressure (1 atm), so the solution freezes at °C.
The result is a signed temperature. For water, a positive drop always gives a freezing point below 0 °C. Benzene is different: it freezes at 5.5 °C, so a solution with a drop smaller than 5.5 °C still freezes above 0 °C. At zero molality the drop is zero and the solution freezes at exactly the pure solvent's freezing point.
Built-in solvent constants
| Solvent | Pure freezing point (1 atm) | Cryoscopic constant |
|---|---|---|
| Water | 0 °C | 1.86 °C·kg/mol |
| Benzene | 5.5 °C | 5.12 °C·kg/mol |
The calculator supports only these two preset solvents. It has no custom-solvent field and no pressure input.
Choosing the van 't Hoff factor
The van 't Hoff factor describes how many independent particles each unit of solute produces in solution.
- For a solute that stays as intact molecules, such as glucose in water, use .
- If the solute dissociates into ions, the effective particle count rises, so is larger.
- If solute particles associate, the effective count falls, so is smaller.
The calculator does not guess the factor; you enter it. It accepts values from 0.1 to 5. In real mixtures, the effective factor can shift with concentration, so use a value appropriate to your mixture and concentration when you have one. The default is 1.
Entering values in Freezing point mode
| Input | Default | Accepted values |
|---|---|---|
| Solvent | Water | Water or Benzene |
| Van 't Hoff factor (i) | 1 | 0.1–5 |
| Solute molality | 0.50 mol/kg | Exactly 0, or 1e-12–5 mol/kg |
Range endpoints are inclusive. You can type finite decimal or scientific notation (for example 5e-3). The factor slider moves in steps of 0.1 and the molality slider in steps of 0.05 mol/kg. The results are the Solution freezing point and the Freezing point drop, both in °C.
Calculating molar mass from a freezing point drop
If you have measured how far a solution's freezing point fell, you can infer how many moles of solute you dissolved, and therefore its molar mass. This is the basis of molar mass determination by freezing point depression.
Rearrange the depression equation for molality, convert to moles using the solvent mass, then divide the solute mass by the moles:
Here is the inferred amount of solute in mol, is the solvent mass in kilograms (the calculator divides the grams you enter by 1,000), is the solute sample mass in grams, and is the estimated molar mass in g/mol.
Worked example
Suppose 9 g of a solute is dissolved in 100 g of water, and the freezing point drops by 0.93 °C. Take and °C·kg/mol.
- Molality: mol/kg.
- Solvent mass: kg.
- Moles of solute: mol.
- Molar mass: g/mol.
This matches the calculator's Lab · 0.93 °C drop in water example, which gives 0.05 mol and 180 g/mol.
Entering values in Molar mass mode
| Input | Default | Accepted values |
|---|---|---|
| Solvent | Water | Water or Benzene |
| Van 't Hoff factor (i) | 1 | 0.1–5 |
| Measured freezing point drop | 0.93 °C | 0.001–20 °C |
| Solute mass | 9 g | 0.001–1,000 g |
| Solvent mass | 100 g | 0.001–10,000 g |
The Measured freezing point drop is the pure solvent's freezing point minus the measured solution freezing point, expressed as a positive number of °C. Both freezing points must be compared at the same pressure. The calculator does not accept a raw solution temperature, so do the subtraction first. For instance, if a water-based solution freezes at −0.93 °C, enter 0.93.
The initial lab slider ranges are 0.01–2 °C for the drop, 0.1–25 g for solute mass, and 1–250 g for solvent mass. Typing a larger value within the accepted range can expand the slider's upper limit.
Note how the factor affects the answer. With the drop and masses fixed, doubling halves the inferred amount of solute and doubles the estimated molar mass, so choosing the wrong factor directly distorts the result.
Using the examples and controls
The Example selector offers two presets, both using water and :
- Water · 0.50 mol/kg loads Freezing point mode with 0.50 mol/kg.
- Lab · 0.93 °C drop in water loads Molar mass mode with a 0.93 °C drop, 9 g of solute, and 100 g of solvent.
Editing an input or switching modes changes the selector to Custom values. Reset returns to the Water example and restores the sample inputs in both modes. Copy saves your active inputs and results to the clipboard, and Export opens the browser's print dialog. Inputs belonging to the inactive mode are ignored.
Reading the results and the diagram
Results show up to four significant digits. Scientific notation is used for nonzero magnitudes below 0.001 and for magnitudes of 100,000 or greater. Internally, the calculator keeps full floating-point precision and does not round between steps.
The comparison diagram labels the pure solvent's freezing point, the solution's freezing point, and the difference between them. The gap widens as the drop grows. Marker spacing is schematic, not a calibrated temperature scale. In Molar mass mode, the diagram also shows the inferred amount of solute in mol and how sample mass, amount, and molar mass relate.
If a required input is blank or invalid, the field is highlighted, the results show a dash, the diagram is hidden, and Copy is disabled until the input is fixed. A nonzero value too small to be represented as a nonzero number is rejected.
The dilute-solution notice
When the effective particle molality reaches 1 mol/kg or more, the calculator shows Check the dilute-solution assumption. That quantity is in Freezing point mode and in Molar mass mode. The notice is a prompt to compare the estimate with measurements or with an effective factor for that concentration. It is not a universal physical cutoff.
Assumptions and limitations
- The linear equation models a dilute solution with a nonvolatile solute, where solid solvent separates at the equilibrium onset of freezing.
- Built-in pure-solvent freezing points apply at normal pressure.
- The accepted input ranges are software limits. Whether the model fits your solution depends on the solution itself.
- Use the equilibrium freezing point in lab work. If a sample supercools, the lowest temperature reached is below the true freezing point, which makes the measured drop too large and the estimated molar mass too low.
- The calculator does not model supercooling, other phase changes, or experimental uncertainty.
- Its scope is freezing point depression and the inverse molar-mass estimate. It does not calculate osmotic pressure or generate lab reports.
Frequently asked questions
How do I calculate the freezing point of a solution?
Compute the drop with , then subtract it from the pure solvent's freezing point. For 0.50 mol/kg of a non-dissociating solute in water, the drop is 0.93 °C and the freezing point is −0.93 °C.
What is the difference between freezing point depression and the freezing point of the solution?
The depression is the size of the drop and is zero at zero molality. The solution's freezing point is the actual temperature, found by subtracting the drop from the pure solvent's freezing point.
Why is my result above 0 °C?
That happens with benzene, whose pure freezing point is 5.5 °C. A drop smaller than 5.5 °C leaves the solution freezing above 0 °C.
What if my solute dissociates into ions?
Use an effective van 't Hoff factor greater than 1 that suits your mixture and concentration. Because the drop scales with , an incorrect factor changes the result proportionally.
Can I enter the measured solution temperature directly?
No. Enter the difference between the pure solvent's freezing point and the solution's freezing point in Measured freezing point drop.
Why might my experimental molar mass be too low?
Supercooling is a common cause. If you record a minimum temperature below the equilibrium freezing point, the drop appears too large, and the estimated molar mass comes out too low.
Read the formula definitions, supported input ranges, and limitations before using this estimate.